5.2.
SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED
BY THE GLOBAL FRAME STATUS
The FRAME STATUS jumper located at the front of the module determines whether local faults (as shown
by the Local Fault indicator) will be connected to the 7700FR frame's global status bus.
FRAME STATUS
STATUS LED's and on the Frame's Fault Tally output) install this jumper in the On position.
On Rev A and B boards install the jumper. (default)
When this jumper is installed in the Off position local faults on this module will not be
monitored. On rev Rev A and B boards remove the jumper and re-install it so that only one
side is connected.
5.3.

SETTING THE EQUALIZER WARNING THRESHOLD

The EQ trimpot R28 located near jumper J8 is used to set the threshold of the cable equalizer warning.
The equalizer warning is factory set to 125 meters of Belden 1684 cable, but may be adjusted for other
cable types or cable lengths. To adjust the cable equalizer warning threshold, connect a signal to the
input of the DA using the required length of cable. Adjust the trimpot slowly until the Equalizer warning
LED comes on. You can verify that the equalizer warning is operating correctly by removing a few meters
of cable from the input. The LED should go off.