Completing The Upgrade; Upgrading The Firmware - File Transfer Protocol Over Ethernet; Servicing Instructions; Changing The Fuses - evertz HD9626DSK Instruction Manual

High definition downstream keyer series
Hide thumbs Also See for HD9626DSK:
Table of Contents

Advertisement

HD9626DSK Instruction Manual
If the unit does not automatically restart, then type the word "boot", without quotes, and press the
<enter> key once.
15. The following is a list of possible reasons for a failed upload:
If you get the message "transfer cancelled by remote" you must restart the terminal program
and load the bin file.
The supplied "*.bin" file is corrupt.
Wrong file specified to be uploaded.
Wrong file transfer protocol used – make sure to specify Xmodem, not Xmodem 1K.
The PCs' RS-232 communications port cannot handle a port speed of 57600.
Noise induced into the Serial Upgrade cable.

Completing the Upgrade

5.2.6.
16. You can now close the terminal program and disconnect the RS-232 serial cable from the PC.
5.3.
UPGRADING THE FIRMWARE – FILE TRANSFER PROTOCOL OVER ETHERNET
The Overture™ software can be used to update the firmware in Evertz HD9626DSK Keyer unit using
File Transfer Protocol (FTP). Overture™ allows the user to upload the same firmware to multiple units
at the same time with the same 'drag and drop' ease that you use to upload media files to the keyer
units. For more information see the Overture™ User manual.
5.4.

SERVICING INSTRUCTIONS

CAUTION – These servicing instructions are for use by qualified service
personnel only. To reduce risk of electric shock, do not perform any servicing
instructions in this section of the manual unless you are qualified to do so.

5.4.1. Changing the Fuses

Check that the line fuse is rated for the correct value marked on the rear panel.
Never replace with a fuse of greater value.
The fuse holder is located inside the power entry module. To change the fuses, disconnect the line
cord from the power entry module and pull out the fuse holder from the power entry module using a
small screwdriver. The fuse holder contains two fuses, one for the line and one for the neutral side of
the mains connection. Pull out the blown fuse and place a fuse of the correct value in its place. Use
slo blo (time delay) 5 x 20 mm fuses rated for 250 Volts with a current rating of 1, shown in Table 5-1.
Carefully reinsert the fuse holder into the power entry module.
Page 5-8
Model
HD9626DSK

Table 5-1: Fuse Ratings

Revision 1.4
Fuse Rating
1 amp