Recalling A User Preset; Storing A User Preset; Viewing The Preset Settings; Table 3-5: Top Level Of The Preset Setup Menu - evertz HD9626DSK Instruction Manual

High definition downstream keyer series
Hide thumbs Also See for HD9626DSK:
Table of Contents

Advertisement

HD9626DSK Instruction Manual
Recall Preset
Store Preset
Export Preset
Preset Source
GPI Setup
GPO Setup

3.9.1. Recalling a User Preset

PRESET
Recall Preset
Recall # 1

3.9.2. Storing a User Preset

PRESET
Store Preset
Store # 1
3.9.3.

Viewing the Preset Settings

PRESET
Export Preset
dump preset # 1
Page 3-16
Recalls 1 of the 10 user presets to the Preview bus
Stores the Program bus settings to 1 of the 10 user presets
Dumps the preset settings to the Upgrade RS-232 serial port
Selects whether the settings of the Preview bus or the Program bus will
be saved as a preset
Configures the General Purpose Inputs
Configures the General Purpose Outputs

Table 3-5: Top Level of the Preset Setup Menu

This menu item is used to recall 1 of the 10 user presets to the Preview
bus.
Use the
or
pushbuttons to select the preset to recall. When you press
the SELECT button the preset will be recalled to the preview bus
overwriting the active settings. These settings will show on the program
bus when the TAKE button is pressed, or a GPI trigger invokes the
transition.
This menu item is used to store the preset settings to 1 of the 10 user
presets.
Use the
or
pushbuttons to select the preset to save the settings to.
When you press the SELECT button the settings will be saved overwriting
any preset that was previously stored at that location.
This menu item is used to dump the preset settings to the Upgrade RS-232
serial port.
Use the
or
pushbuttons to select the preset to dump. When you press
the SELECT button the settings are output in readable text to the Upgrade
RS-232 port.
To view the settings, use a terminal program with the
following configuration: baud rate: 57600, data bits: 8, parity: none, stop
bits: 2.
This feature is used for information purposes only. The data cannot be
used to send the preset to another unit.