3.5.7. Displaying the Genlock Status

GENERAL
Genlock Status
Ref is unlocked
Ref is locked

3.5.8. Setting the M2100 Unit Name

GENERAL
Unit Name
EVZ1
...
EVZ8

3.5.9. Automation Debug Functions

Two automation debug functions are provided in the GENERAL menu.
automation protocol and is called Automation Debug. The other is for the M2100 automation protocol
and is called M2100 Auto Debug. Both functions work in essentially the same way. When you turn on
one of the automation debug functions, the data packets being received from the automation system
are output to the Upgrade RS-232 serial port. To view the data, use a terminal program with the
following settings: baud rate: 57600, data bits: 8, parity: none, stop bits: 2, flow control: none.
These functions are used to view the commands that are being sent by the automation system. If you
are having problems with a unit that is being controlled from automation, Evertz service personnel may
ask you to provide a capture of the data being output on the serial port when the debug function is
turned on.
3.6.

MATTE CONFIGURATION ITEMS

The HD9626DSK Downstream Keyer has a black overlay matte that blacks out video and produces a
letterbox effect on the output video. The MATTE Setup menu is used to configure the matte that can
be applied over the program video. Table 3-2 shows the items available in the MATTE Setup menu.
Sections 3.6.1 to 3.6.3 provide detailed information about each of the sub-menus.
Page 3-10
This menu item allows you to set the communications protocol that will be
used on the virtual serial port COM E. The use of a serial to Ethernet
converter is required to use COM E.
The same functions are available for COM E as for COM D, however, it is
not recommended to use COM E for any of the automation protocols since
TCP/IP traffic does not guarantee frame accurate control.
This menu item displays the status of the keyer in regards to genlock. The
status will indicate whether the keyer is locked to reference or not.
This menu item allows the user to set the unit name required when the
HD9626DSK is used in conjunction with a M2100 control panel. Each
keyer connected to the panel must have a unique name assigned.
Revision 1.4
One is for the Evertz
OPERATION