Connector Assignments - Kollmorgen S70601-SE Instruction Manual

Digital servo amplifier sto single channel
Table of Contents

Advertisement

Kollmorgen
10.1.2.5

Connector assignments

The functions are adjustable with the setup software. In the table below the default values
are described.
Connector X11A
Pin Dir
1
2
3
4
5
6
7
8
9
10
11
12
Connector X11B
1
2
3
4
5
6
7
8
9
10 Out
11
12
S701...S724 (single channel STO) Instruction Manual
Default
Description
function
In
A0
Motion block number, LSB
In
A1
Motion block number, 2
In
A2
Motion block number, 2
In
A3
Motion block number, 2
In
A4
Motion block number, 2
In
A5
Motion block number, 2
In
A6
Motion block number, 2
In
A7
Motion block number, MSB
Polls the home switch. If a digital input on the base unit is
In
Reference
used as a home input, then the input on the expansion card
will not be evaluated.
Clears the warning of a following error (n03) or the response
In
F_error_clear
monitoring (n04)
The following task, that is defined in the motion task by "Start
with I/O" is started. The target position of the present motion
In
Start_MT_Next
task must be reached before the following task can be started.
The next motion block can also be started by an appropriately
configured digital input on the base unit.
Starts the "Jog Mode" with a defined speed. "x" is the speed
In
Start_Jog v= x
saved in the servo amplifier for the function "Jog Mode". A ri-
sing edge starts the motion, a falling edge cancels the motion.
In
MT_Restart
Continues the motion task that was previously interrupted.
Starts the motion task that is addressed by A0-A7 (connector
In
Start_MT I/O
X11A/1...8).
When the target position for a motion task has been reached
Out
InPos
(the InPosition window), this is signaled by the output of a
HIGH signal. A cable break will not be detected.
The start of each motion task in an automatically executed
sequence of motion tasks is signaled by an inversion of the
Next-InPos
output signal. The output produces a LOW signal at the start
Out
of the first motion task of the sequence. The form of the mes-
sage can be varied by using ASCII commands.
PosReg 0
Can only be adjusted by ASCII commands/setup software.
A LOW signal indicates that the position has gone outside the
Out
F_error
acceptable following error window.
Out
PosReg1
default: SW limit 1, indicated by a HIGH signal
Out
PosReg2
default: SW limit 2, indicated by a HIGH signal
Out
PosReg3
Can only be adjusted by ASCII commands/setup software.
Out
PosReg4
Can only be adjusted by ASCII commands/setup software.
PosReg5
Can only be adjusted by ASCII commands/setup software.
-
24V DC
Supply voltage for output signals.
-
I/O-GND
Digital GND for the control system.
12/2010a
1
2
3
4
5
6
Expansions
109