Kollmorgen
Minimum Wiring for Drive Test
This wiring does not fulfill any requirements to safety or functionality of your
application, it just shows the required wiring for drive testing without load.
24V ON
+
24V DC
-
Power ON
S701...S724 (single channel STO) Instruction Manual
12/2010a
1
Enable
X3A/1
X4A/1
X3B/16
X3B/14
X4A/2
X8/3
X8/4
Power
Setup
Feedback
X3B/15
X4B/4
X4B/6
Motor
Power
93