Section 4 - Specifications; Serial Number And Rating Label Location; Software Licensing Agreement; Information About Default Weld Parameters And Settings - Miller Millermatic 355 Owner's Manual

Table of Contents

Advertisement

4-1.

Serial Number And Rating Label Location

The serial number and rating information for this product is located on the back of unit. Use rating label to determine input power requirements
and/or rated output. For future reference, write serial number in space provided on back cover of this manual.
4-2.

Software Licensing Agreement

The End User License Agreement and any third-party notices and terms and conditions pertaining to third-party software can be found at
https://www.millerwelds.com/eula
4-3.

Information About Default Weld Parameters And Settings

NOTICE – Each welding application is unique. Although certain Miller Electric products are designed to determine and default to certain typical
welding parameters and settings based upon specific and relatively limited application variables input by the end user, such default settings are
for reference purposes only; and final weld results can be affected by other variables and application-specific circumstances. The appropriate-
ness of all parameters and settings should be evaluated and modified by the end user as necessary based upon application-specific require-
ments. The end user is solely responsible for selection and coordination of appropriate equipment, adoption or adjustment of default weld
parameters and settings, and ultimate quality and durability of all resultant welds. Miller Electric expressly disclaims any and all implied warran-
ties including any implied warranty of fitness for a particular purpose.
4-4.

Unit Specifications

Do not use information in unit specifications table to determine electrical service requirements. See Sections 5-3 thru 5-4 for information on
connecting input power.
This equipment will deliver rated output at an ambient air temperature up to 104°F (40°C).
Input Power
Rated Output
310 A at 29.5
3–Phase
VDC, 60% Du-
ty Cycle*
310 A at 29.5
1–Phase 460/
VDC, 60% Du-
575V
ty Cycle*
310 A at 29.5
1–Phase 208/
VDC, 60% Du-
240V
ty Cycle*
*See Section 4-7 for Duty Cycle Rating.
4-5.

Environmental Specifications

A. IP Rating
B. Temperature Specifications
Operating Temperature Range*
-22 to 122°F (-30 to 50°C)
*Output is derated at temperatures above 104°F (40°C).
SECTION 4 – SPECIFICATIONS
and are incorporated by reference herein.
Voltage
Max Output
Range
400 A at
34VDC, 25%
12–34 V
Duty Cycle*
400 A at
34VDC, 25%
12–34 V
Duty Cycle*
350 A at
32VDC, 35%
12–32 V
Duty Cycle*
This equipment is designed for outdoor use.
RMS Amps Input at Rated Load
Max Open-
Circuit
Voltage
208 V
240 V
32.3
28.8
95 VDC
69.6
62.5
IP Rating
IP23
Storage/Transportation Temperature Range
-40 to 149°F (-40 to 65°C)
Output
KVA
460 V
575 V
18.2
15.4
15.3
35.6
32.3
15.0
15.0
OM-288360 Page 13
KW
11.5
11.1
11.1

Advertisement

Table of Contents
loading