Main Menu; Main Menu Options - Honeywell Home T10 Product Data

Smart thermostat with redlink 3.0
Hide thumbs Also See for T10:
Table of Contents

Advertisement

MAIN MENU

From Home Screen, press the Menu icon at bottom of the
display (3 horizontal lines). (If this is not shown at home
screen, touch screen to wake display first).

Main Menu Options

Notifications
Only displayed when there are active alerts/notifications.
select "Notifications" to see details.
System Mode
(Available modes vary depending on how the thermostat was
configured)
• Heat
• Off
• Cool
• Auto (see "Auto Changeover Operation" on
page 59)
• Em Heat (see "Em Heat and Auxiliary Heat
Operation" on page 59)
Fan
(Fan setting not available for all system types)
• Auto (Fan only runs with a call for heat or cool, or if
set to run with Hum, dehum, or vent call)
• On (fan runs continuous)
• Circulate (fan runs randomly approx. 33% of the
time)
Priority
If wireless indoor temperature/humidity/motion sensors are
used, select which sensors are used for temperature
control. Can choose active sensor (ones detecting motion)
or manually select which sensors to use.
Schedule
• Create new schedule – (Set a time-based schedule)
• Disable schedule
• Reset to default Schedule
NOTE: To enable Geofencing, use the Resideo app.
Weather
Shown if connected to Wi Fi/App, & ISU 1060 = Internet,
displays weather forecast for up to 10 hours in 2 hour
increments.
Temperatures
Shown if configured for a floor/slab sensor in ISU 1055.
Shows the temperature reading and settings for Floor sensor
(T10+ only).
Humidification
• View current indoor humidity level & setting
• View humidifier status (humidifying, idle, off)
• Change humidity setting
• Options change mode, change window protection
setting
Dehumidification
• View current indoor dehumidity level & setting
• View dehumidifier status (dehumidifying, idle, off)
• Change dehumidity setting
• Options change mode, adjust high speed fan priority
setting
Ventilation
• View or change mode (auto, on, off)
• Timed ventilation 180 minutes max
• Options lockout settings for sleep, high outdoor
temperature, low outdoor temperature, high outdoor
dew point
If ISU 10005 = VNT5070E1000 or VNT5200E1000, the
ventilation menu will show CFM and watts of the ventilator
while ventilator is running.
Temperature balancing (T10+ only). Shown if ISU 3310 is
enabled.
• Auto or off.
When set to auto, you can adjust the Room delta setting from
.5°F to 10°F in .5°F increments (.25°C to 5°C in .25°C
increments). This will allow the T10+ to run the fan if the
temperature between sensors selected under "options" in the
Temperature balancing menu.
47
33-00462—05

Advertisement

Table of Contents
loading

This manual is also suitable for:

T10+ pro