Firmware is occasionally updated at the factory or over the air. Some ISU settings may not be shown on models that lack the latest firmware.
ISU #
Heading
9190
Dehumidification Dehumidification Away
mode Fan Control
9200
Dehumidification Dehumidification Away
mode low limit
temperature setting
Dehumidification Away
Mode Temperature
Setting
Dehumidification Away
Mode Dehumidification
Setting
9210
Dehumidification Dehumidifier Filter
replacement reminder
10000 Ventilation
Ventilation Type
10005 Ventilation
Ventilator Model number Other model
10020 Ventilation
What terminals are wired
to the ventilation
equipment?
10050 Ventilation
Ventilation control
method
10060 Ventilation
Ventilation Fan control
10065 Ventilation
Turn on ventilation dry
contacts
10090 Ventilation
Ventilation House Size
Table 9. Installer Setup (ISU). (Continued)
Question
Options
On, automatic, circulate
70-80F (21.0C-26.5C)
70F to 99F (21.0C to 37.0C) 9180 = allowed No
40% - 70%
Off, 30, 60, calendar days;
3, 4, 5, 6, 7, 8, 9, 10, 11, 12,
calendar months.
None, ERV/HRV, Passive
(Fan Only), Fresh Air
Damper,
VNT5070E1000
VNT5200E1000
None, EIM U1, EIM U2, EIM
U3
ASHRAE or Percent on
Time
Thermostat controls fan or
Equipment controls fan
Custom Alert 1 - Custom
Alert 4 (options depend on
6005 settings)
Number of Bedrooms 1-6
Size of house 1000 -5000
sq. ft. if display set to
Fahrenheit; 90-460 sq. M. if
set to Celsius
Contingent
previous
EIM
setting?
needed?
9180 = allowed No
9180 = allowed No
9180 = allowed No
No
ERV/HRV or
No
damper needs
Available U
contacts.
"Passive Fan"
not an option
for Radiant
heat only.
ISU 10000 set
No
to ERV/ HRV
10000 =
Yes
ERV/HRV or
Fesh air
damper
10000 =
No
ERV/HRV or
Fesh air
damper
10000 =
No
ERV/HRV or
Fresh air damper
And 8000 set for
humidifier
ISU 6005 is set
Yes
for a custom
dry contact
alert & ISU
10140 isn't
selected for the
same custom
alert.
10050 =
No
Ashrae
10050 =
No
Ashrae
41
T10, T10+
or both
Notes
T10+
T10+
The
dehumidification
Away mode setting
can restrict this
T10+
The
dehumidification
Away mode Low
Limit setting can
restrict this
T10+
Both
Both
T10+
Information in
Ventilation section
T10+
If an EIM is not
used this ISU isn't
shown and
ventilator wires to U
contacts at UWP
Both
Both
T10+
If enabled, the
ventilator will come
on whenever
the selected Dry
Contact Alert is
active
Both
Both
33-00462—05