Firmware is occasionally updated at the factory or over the air. Some ISU settings may not be shown on models that lack the latest firmware.
ISU #
Heading
3090
Staging control Backup heat differentials Stage 1: Comfort*, 2.0F to
3110
Staging control Backup heat upstage
timer
Backup heat holdoff timer auto, 15, 30, 45, 60, 75, 90,
3120
Equipment
Compressor
Lockouts
Lockout/Balance point
Backup Heat Lockout
3125
Equipment
Fan Lockout after cool
Lockouts
call ends
3140
Cycle rates
Cool Cycles Per hour
Compressor Cycles Per
Hour
3150
Cycle rates
Radiant heat cycles per
hour
Heat Cycles per hour
3160
Cycle rates
Backup heat cycles per
hour
Backup heat cycles per
hour
Table 9. Installer Setup (ISU). (Continued)
Question
Options
15F (1.00C to 7.5C)
Stage 2: Comfort*, 2.5F to
15.5F (1.25F to 7.75F)
off, 30, 45, 60, 75, 90
minutes, 2, 3, 4, 5, 6, 8, 10,
12, 14, 16 hours
105, 120 minutes
Off, -15F to 50F (-26.0 to
15.5C)
Off, 55F to 65F (-15 to 18.5
C)
Off, 5-120 minutes in 5
minute increments
stage 1. Settings 1-6
stage 2. Settings 1-6
stage 1. Settings 1-6
stage 2. Settings 1-6
stage 1, settings 1-12
stage 2, settings 1-12
stage 1. Settings 1-12
stage 2. Settings 1-12
stage 3. Settings 1-12
backup heat cycles per
hour. Settings 1-12
backup heat cycles per hour
stage 2. settings 1-12
Contingent
previous
EIM
setting?
needed?
Heat pump
No
selected with 1
or 2 backup
heat stages
Heat pump
Yes
selected with 2
backup heat
stages
3090 set for
No
other than
"Comfort"
Upstage timer
No
set to other
than "Off".
Configured for
No
heat pump with
an aux heat
No
stage
2070 =
No
at least 1
cool/compressor
stage
2000 = other
No
than heat
pump. 2070 =
1 or 2
2000 = other
No
than heat
pump. 2070 =
2
2000 = heat
No
pump
2000 = heat
No
pump, 2070 =
2
At least 1
No
radiant heat
stage
2 radiant heat
No
stages
2000 =
No
Conventional
forced air, or
other
2000 =
No
Conventional
forced air &
2070 = 2-3
heat stages
2000 =
Yes
Conventional
forced air &
2070 = 3 heat
stages
2130 = at least
No
1 backup heat
stage selected
2130 = 2
Yes
backup heat
stage selected
35
T10, T10+
or both
Notes
Both
*Comfort setting not
available for dual
fuel
T10+
Both
See section on
upstage timer and
T10+
holdoff timer
Both
Both
T10+
This locks out the
fan after a cool call
even if the fan is set
to On or Circ mode
or if the fan is set to
run for air
temperature
balancing.
Both
Both
Both
Both
Both
T10+
Both
Both
T10+
Both
T10+
33-00462—05