Honeywell Home T10 Product Data page 44

Smart thermostat with redlink 3.0
Hide thumbs Also See for T10:
Table of Contents

Advertisement

Firmware is occasionally updated at the factory or over the air. Some ISU settings may not be shown on models that lack the latest firmware.
ISU #
Heading
8070
Humidification Humidification control
Humidifier Lockouts Dry
8095
Humidification
Contacts
8100
Humidification Humidifier Pad
replacement reminder
8100
Humidification Clean tank/Water Filter
replacement Reminder
9000
Dehumidification What type of
dehumidification
equipment do you have?
9005
Dehumidification Dehumidification Fan
speed priority
9010
Dehumidification What sensors will be
used for Humidification
control
9040
Dehumidification What terminals are wired
to the Dehumidification
Equip.?
9050
Dehumidification Dehumidification
Equipment Setup
9070
Dehumidification Dehumidification -
Overcooling Limit
9120
Dehumidification System modes allowing
dehumidification
9130
Dehumidification Dehumidifier Fan Control Thermostat controls Fan,
9140
Dehumidification Dehumidifier Lockout
9145
Dehumidification Dehumidifier lockout dry
contact
9180
Dehumidification Dehumidification - Away
mode
33-00462—05
Table 9. Installer Setup (ISU). (Continued)
Question
Options
- Humidify Only when heat
is on
- Humidify Only when fan
is on
- Humidify on demand:
Thermostat controls fan
- Humidify on demand:
Humidifier controls fan
Full drain pan,
water leak,
Custom Alert 1-Custom Alert 4
Off, 6 or 12 calendar months 8000 = none,
Off, 60, or 90 run time days,
6 or 12 calendar months
None, A/C with low speed
fan, A/C with high speed
fan, Whole House
Dehumidifier
Low speed fan with cool
stage 1 only, Low speed fan
always, user selectable
Options shows thermostat
and wireless sensors
None, EIM U1, EIM U2, EIM
U3
Normally Open, Normally
Closed
0, 1, 2, 3F (0C, 0.5C, 1.0C,
1.5C)
Heat, off, cool
Dehumidifier Controls Fan
Dehumidifier Allowed when
Cool is Running,
Dehumidifier Not Allowed
when Cool is Running
Custom Alert 1 -
Custom Alert 4 (options
depend on 6005 settings)
Not allowed, Allowed
Contingent
previous
EIM
setting?
needed?
8000 set to
No
other than
"None"
8000 = steam,
by-pass or fan
powered, &
6000 = full
drain pan or
Yes
water leak, OR
6005 is set for
custom Dry
Contact Alert
No
or bypass or
fan powered
8000 = steam
No
A/C with low
No
speed fan &
Whole House
Dehumidifier
only shown if U
contacts
available
9000 = A/C
No
with low speed
fan
9000 = other
No
than "None" &
wireless
sensor
connected to
thermostat
9000 = A/C
Yes
with low speed
fan or Whole
House
Dehumidifier
9000 = AC with
No
low speed fan
9000 = A/C
No
with high or
low speed fan
9000 - Whole
No
House
Dehumidifier
9000 - Whole
No
House
Dehumidifier
9000 - Whole
No
House
Dehumidifier
ISU 6005 is set
Yes
for a custom
dry contact
alert
No
40
T10, T10+
or both
Notes
Both
This will lock out the
humidifier when the
T10+
associated Dry
Contact Alert is
active
Both
Both
Both
T10+
T10+
T10+
If an EIM is not
used this ISU isn't
shown and
dehumidifier wires
to U contacts at
UWP
Both
Both
Both
Both
Both
T10+
If enabled, the
dehumidifier will
lock out whenever
the selected Dry
Contact Alert is
active
T10+

Advertisement