Honeywell Home T10 Product Data page 25

Smart thermostat with redlink 3.0
Hide thumbs Also See for T10:
Table of Contents

Advertisement

Fig. 43. Typical wiring EIM to a Resideo TrueZONE forced air zone panel for heat pump with electric aux heat application
Fig. 44. Typical wiring EIM to a Resideo TrueZONE forced air zone panel for dual fuel heat pump application
THM04R3000
1
R TO Rc JUMPER REMOVED IF EIM IS POWERED BY A SEPARATE TRANSFORMER.
2
ZONE 4 IS SHOWN IN THIS DRAWING. THE EIM CAN WIRE TO ANY ZONE ON THE TRUEZONE PANEL.
3
Y2 IS FOR 2 STAGE COMPRESSOR ONLY.
4
ADD A JUMPER FROM W1/E TO W3 AT ZONE PANEL IF Y2 IS USED. ADD A JUMPER AT ZONE PANEL FROM W1/E
TO W2 IF Y2 IS OT USED.
5
WIRE THE DAMPERS, TRANSFOMER AND HVAC TO ZONE PANEL AS SHOWN IN ZONE PANEL INSTALLATION GUIDE.
6
IT IS NOT RECOMMENDED TO USE A DISCHARGE SENSOR WITH THE EIM ON A ZONED SYSTEM. A DISCHARGE
SENSOR CAN BE WIRED TO THE ZONE PANEL FOR HIGH AND LOW LIMIT TEMPERATURE PROTECTION.
THM04R3000
1
R TO Rc JUMPER REMOVED IF EIM IS POWERED BY A SEPARATE TRANSFORMER.
ZONE 4 IS SHOWN IN THIS DRAWING. THE EIM CAN WIRE TO ANY ZONE ON THE TRUEZONE PANEL.
2
3
W2 IS FOR 2 STAGE FURNACE ONLY.
4
Y2 FOR 2 STAGE COMPRESSOR ONLY.
5
WIRE THE DAMPERS, TRANSFOMER AND HVAC TO ZONE PANEL AS SHOWN IN ZONE PANEL INSTALLATION GUIDE.
6
IT IS NOT RECOMMENDED TO USE A DISCHARGE SENSOR WITH THE EIM ON A ZONED SYSTEM. A DISCHARGE
SENSOR CAN BE WIRED TO THE ZONE PANEL FOR HIGH AND LOW LIMIT TEMPERATURE PROTECTION.
R
C
2
L
O/B
W1
W2
AUX1
W3
AUX2
3
Y1
Y2
G
1
RH
RC
R
C
R
C
2
L
O/B
W1
W2
AUX1
W3
AUX2
3
Y1
Y2
G
1
RH
RC
R
C
21
M1
M4
M6
R
C
W1/E
W2
4
W3
Y1
Y2
G
O/B
L
HZ432
5
6
M39213
M1
M4
M6
R
C
W1/E
W2
4
W3
Y1
Y2
4
G
O/B
L
HZ432
5
6
M39214
33-00462—05