Wiring Dry Contact Alerts With Eim - Honeywell Home T10 Product Data

Smart thermostat with redlink 3.0
Hide thumbs Also See for T10:
Table of Contents

Advertisement

Wiring Dry Contact Alerts with EIM

MULTIPLE DRY CONTACT DEVICES
TYPICAL HOOKUP OF HUMIDIFIER WITH BUILT-IN
TRANSFORMER
24
U1
HUMIDIFIER
VAC
U1
U2
U2
U3
U3
TYPICAL HOOKUP OF HUMIDIFIER POWERED BY
HVAC TRANSFORMER
RH
RC
24
120
R
VAC
VAC
C
U1
U1
HUMIDIFIER
U2
U2
U3
U3
TYPICAL HOOKUP OF A BASIC BYPASS HUMIDIFIER
POWERED BY A DEDICATED TRANSFORMER
U1
24
120
U1
VAC
VAC
U2
3
U2
OPTIONAL AIR-
U3
FLOW SENSOR
U3
HUMIDIFIER
TYPICAL HOOKUP OF AN ADVANCED BYPASS
HUMIDIFIER POWERED BY A DEDICATED TRANSFORMER
U1
3
VAC
U1
OPTIONAL
U2
AIR-FLOW
SENSOR
U2
U3
U3
1
ANY COMBINATION OF RELAYS (U1, U2, U3) CAN BE USED. THEY ARE SET IN THE THERMOSTAT INSTALLER SETUP.
2
WIRE THE U RELAY TO THE LOW SPEED FAN FOR DEHUMIDIFICATION CONTROL AT THE EQUIPMENT. THE EIM RELAY CAN BE SET TO BE NORMALLY- OPEN OR NORMALLY-CLOSED IN
THE THERMOSTAT INSTALLER SETUP.
3
AN OPTIONAL 50027910-001 AIR-FLOW SWITCH (AFS) OR IS RECOMMENDED TO ENSURE AIR FLOW WHEN THE HUMIDIFIER IS RUNNING. IF THE AFS IS USED, SET DIP SWITCH 1 TO
OFF (LEFT). THE T10+ CAN BE CONFIGURED TO ONLY RUN THE HUMIDIFIER WITH A CALL FOR HEAT OR FAN, SO THE AFS WOULD ONLY BE NEEDED TO ENSURE NO WATER FLOW
THROUGH THE HUMIDIFIER PAD IF THERE IS A FAN FAILURE. THE T10+ CAN ALTERNATELY BE CONFIGURED FOR A FAN FAILURE ALERT (ISU 6000, 6150 AND 6160).
Fig. 46. "U" terminals can be used for humidification, dehumidification or ventilation
33-00462—05
ONE DRY CONTACT DEVICE
ON ONE SET OF TERMINALS
Fig. 45. Dry contact alerts
TYPICAL HOOKUP OF AN HM750 STEAM HUMIDIFIER
Main Supply
120
L1 L2/N GND
VAC
Air Proving
Humidistat
External
TYPICAL HOOKUP OF AN EVAPORATIVE FAN
HUMIDIFIER WITH BUILT-IN TRANSFORMER
U1
U1
U2
U2
U3
U3
24
120
VAC
ONE DRY CONTACT DEVICE
EIM
EIM
S3
S1
S3
S1
MULTIPLE DRY CONTACT DEVICES
S4
S2
S4
S2
U1
3
U1
U2
AIR PROVING
U2
(OR JUMPER)
U3
U3
AP
AP
24VAC
COM
HUM
HUM
NORMALLY-OPEN,
DRY CONTACTS
GT
NORMALLY-CLOSED,
RF
DRY CONTACTS
GF
3
OPTIONAL AIR-
FLOW SENSOR
22
ON ONE SET OF TERMINALS
M38718
TYPICAL HOOKUP OF WHOLE HOUSE DEHUMIDIFIER
U1
DEHUMIDIFIER
U1
U2
U2
U3
U3
TYPICAL HOOKUP OF VARIABLE SPEED BLOWER
FOR DEHUMIDIFICATION IN LOW SPEED
RH
RC
24
R
VAC
C
LOW SPEED FAN
U1
CONNECTION
U1
AT FURNACE
U2
NORMALLY-OPEN
U2
U3
U3
TYPICAL HOOKUP OF VENTILATION WITH BUILT-IN
TRANSFORMER
24
U1
VENTILATOR
VAC
U1
U2
U2
U3
U3
TYPICAL HOOKUP OF VENT DAMPER POWERED
BY HVAC TRANSFORMER
RH
RC
24
R
VAC
C
U1
U1
VENT DAMPER
U2
U2
U3
U3
24
120
VAC
VAC
120
VAC
2
120
VAC
120
VAC
M39216