Table 8. Terminals on THM04R3000 Equipment Interface Module (EIM) Used With T10+ Models Only.
Conventional Systems
Terminal
S1, S2, S3, S4
Input for indoor sensor, outdoor sensor, Floor sensor,
(Two of each)
RATS, DATS, or Dry Contact Alert
Y
Compressor Stage 1
Y2
Compressor Stage 2
G
Fan Relay
C
Common from HVAC transformer when R is jumped to Rc.
Common from separate transformer if R is not
jumpered
U1, U2, U3
Relay for humidifier, dehumidifier, or ventilator
(Two of each)
L
Not used for conventional applications
O/B
Not used for conventional applications
W1
Heat Stage 1
W2
Heat Stage 2
W3
Heat Stage 3
R
24V from transformer to power EIM
Rc
24 VAC Cooling transformer
Rh
24 VAC Heat transformer

Setting Slider Tabs

Set R Slider Tab, see Fig. 13.
• Use built-in jumper (R Slider Tab) to differentiate
between one or two transformer systems.
• If there is only one R wire, and it is connected to the
R, Rc, or RH terminal on the old thermostat, set the
slider to the up position (1 wire).
• If there is one wire connected to the R terminal and
one wire connected to the Rc terminal, set the slider
to the down position (2 wires).
9
Fig. 13.
Description
M37789
Heat Pump Systems
Terminal
S1, S2, S3, S4
Input for indoor sensor, outdoor sensor, Floor sensor,
(Two of each)
RATS, DATS, or Dry Contact Alert
Y
Compressor Stage 1
Y2
Compressor Stage 2
G
Fan Relay
C
Common from HVAC transformer when R is jumped to Rc.
Common from separate transformer if R is not
jumpered
U1, U2, U3
Relay for humidifier, dehumidifier, or ventilator
(Two of each)
L
Connect to compressor monitor
O/B
Changeover valve for heat pumps
W1
Not used for heat pump applications
AUX1
Stage 1 of AUX/EM heat
AUX2
Stage 2 of AUX/EM heat
R
24V from transformer to power EIM
Rc
24 VAC Cooling transformer
Rh
24 VAC Heat transformer
Set U Slider Tab, see Fig. 14.
• Use built-in jumper (U Slider Tab) for IAQ device.
• When the U Slider Tab is in the down position (2
wires) the U contacts are a dry set of contacts.
• If your IAQ device is powered by the cooling
transformer, move the U Slider Tab to the up
position (1 wire). When this is done, the lower U
terminal is internally jumped to the Rc terminal. In
this application, you would hook up one wire from
your IAQ device to the upper U terminal and the
other to the common side of the cooling transformer.
The 1 wire setting is most commonly used when
using a fresh air damper for ventilation or using low
speed fan for dehumidification.
• See wiring examples on the next page.