Firmware is occasionally updated at the factory or over the air. Some ISU settings may not be shown on models that lack the latest firmware.
ISU #
Heading
3240
Temperature
Minimum compressor off
Control
time
3250
Temperature
Minimum non-
control
compressor on time
3260
Temperature
Extended fan run times
Control
3300
Temperature
Temperature Balancing
Control
3310
Temperature
Temperature Balancing
Control
Room Delta
4090
Temperature
Adaptive Intelligent
Control
Recovery
4100
Range Stops
Temperature range stops Minimum cool setpoint; 50F-
4110
Keypad
Keypad lockout
lockout
5000
Sensors
What sensors are
WIRED to your system?
5020
Sensors
What Terminals are
Wired to the Indoor
Temperature Sensor?
5030
Sensors
Indoor Temperature
Sensor Type
5040
Sensors
Which Sensors will be
used for
TEMPERATURE
Control? (Multiple
sensors are averaged)
5070
Sensors
What Terminals are
Wired to the Return Air
Temperature Sensor?
5080
Sensors
Return Temperature
Sensor Type
5090
Sensors
What Terminals are
Wired to the Discharge
Air Temperature Sensor?
33-00462—05
Table 9. Installer Setup (ISU). (Continued)
Question
Options
off, 1-5
Off, 2 minutes,
5 minutes,
Extended fan run time in
cool = off, 30, 60, 90
seconds; 2, 3, 4, 5, 6, 7, 8,
9, 10, 11, 12, 13, 14, 15
minutes.
Extended fan run time in
heat = off, 30, 60, 90
seconds; 2, 3, 4, 5, 6, 7, 8,
9, 10, 11, 12, 13, 14, 15
minutes.
Off, On
.5°F to 10°F in .5°F
increments (.25°C to 5°C in
.25°C increments)
No, Yes
99F (10C-37C)
Maximum cool setpoint;
90F-99F (32C-37C)
Minimum heat setpoint;
40F-50F (4.5C-10C)
Maximum heat setpoint;
40F-90F (4.5 - 32.0C)
Unlocked, partially locked,
fully locked
Indoor Air Temperature,
Return Air Temperature,
Discharge Air Temperature,
Floor Temperature
None, EIM S1, EIM S2, EIM
S3, EIM S4
10K, 20K
Thermostat, Indoor sensor
(remote)
None, EIM S1, EIM S2, EIM
S3, EIM S4
10K, 20K
None, EIM S1, EIM S2, EIM
S3, EIM S4
Contingent
previous
EIM
setting?
needed?
2070. At least
No
1
cool/compress
or stage
selected
2000 = radiant
No
heat
At least 1 cool
No
stage
At least 1 heat
No
stage
No
No
At least 1
No
stage of cool
At least 1
No
stage of cool
At least 1
No
stage of heat
At least 1
No
stage of heat
No
"Floor sensor"
No
only shown
here if 1055 is
set to "wired"
5000 has
Yes
Indoor Sensor
selected
5000 has
No
Indoor Sensor
selected
5000 set for
No
wired indoor
sensor
5000 has
Yes
Return sensor
selected
5000 has
No
Return sensor
selected
5000 has
Yes
Discharge
Sensor
selected
36
T10, T10+
or both
Notes
Both
T10+
Both
Both
See "Temperature
T10+
Balancing" section
Both
Both
There is a
correlation between
Both
these settings. For
example, if
minimum cool is set
Both
to 50F, minimum
heat cannot be set
Both
above 40F
Both
Return,
Discharge,
and Floor for
T10+ only.
T10+ with
If an EIM is not
EIM
used this ISU isn't
shown and sensor
wires to S & S at
UWP
Both
Both
T10+
If an EIM is not
used this ISU isn't
shown and sensor
wires to S & S at
UWP
T10+
T10+
If an EIM is not
used this ISU isn't
shown and sensor
wires to S & S at
UWP