Firmware is occasionally updated at the factory or over the air. Some ISU settings may not be shown on models that lack the latest firmware.
ISU #
Heading
6090
Dry Contacts
What terminals are wired
to the Water Leak Alert
dry contacts?
6100
Dry Contacts
Water Leak Alert dry
contact setup
6110
Dry Contacts
What terminals are wired
to the System Shutdown
Alert dry contact?
6120
Dry Contacts
System shut down alert
dry contact setup
6130
Dry Contacts
What terminals are wired
to the Service Needed
Alert dry contact?
6140
Dry Contacts
Service Needed Alert dry
contact setup
6150
Dry Contacts
What terminals are wired
to the Fan Failure Alert
dry contact?
6160
Dry Contacts
Fan Failure Alert dry
contact setup
6190
Dry Contacts
What terminals are wired
to the custom alert 1 dry
contact?
6200
Dry Contacts
Custom alert 1 dry
contact setup
6210
Dry Contacts
Custom Alert 1 Name
6215
Dry Contacts
Show custom alert 1
message
6220
Dry Contacts
Custom Alert 1 Message Type in the message
6230
Dry Contacts
Custom alert 1 actions
6240
Dry Contacts
What terminals are wired
to custom U contact?
6250
Dry Contacts
Custom U dry contact
name
6260
Dry Contacts
Custom U dry contact
setup
6300 -
These are duplicate settings to 6190-6260 but for Dry Contact Alert 2 (if
6370
selected)
6400 -
These are duplicate settings to 6190-6260 but for Dry Contact Alert 3 (if
6470
selected)
6500-
These are duplicate settings to 6190-6260 but for Dry Contact Alert 4 (if
6570
selected)
33-00462—05
Table 9. Installer Setup (ISU). (Continued)
Question
Options
None, EIM S1, EIM S2, EIM
S3, EIM S4
Normally open, normally
closed
None, EIM S1, EIM S2, EIM
S3, EIM S4
Normally open,
normally closed
None, EIM S1, EIM S2,
EIM S3, EIM S4
Normally open,
normally closed
None, EIM S1, EIM S2,
EIM S3, EIM S4
Normally open,
normally closed
None, EIM S1, EIM S2,
EIM S3, EIM S4
Normally open,
normally closed
Type in the alert name
Yes, No
displayed when this alert is
active
Lock out heat, lock out cool,
activate fan, activate custom
U terminal
EIM U1, EIM U2, EIM U3
Type in the name of
whatever the
custom U dry contact is
controlling
Normally open, normally
closed
Contingent
previous
EIM
setting?
needed?
6000 has water
Yes
leak selected
6000 has water
Yes
leak selected
6000 has
Yes
system shut
down alert
selected
Yes
6000 has
Yes
Service
Needed Alert
selected
Yes
6000 has Fan
Yes
Failure Alert
selected
Yes
Yes
6005 has
Yes
custom alert 1
selected
Yes
Yes
6215 set to Yes Yes
6005 has
custom alert 1
selected
6230 has
custom U
Yes
terminal
selected
6005 has
custom
Dry Contact
Yes
Alert 2
selected
6005 has
custom
Dry Contact
Yes
Alert 3
selected
6005 has
custom
Dry Contact
Yes
Alert 4
selected
38
T10, T10+
or both
Notes
T10+
See Dry Contact
alert section for
operation details
T10+
T10+
See Dry Contact
alert section for
operation details
T10+
T10+
See Dry Contact
alert section for
operation details
T10+
T10+
See Dry Contact
alert section for
operation details
T10+
T10+
See Dry Contact
Alert section for
T10+
operation details
T10+
T10+
T10+
See Dry Contact
Alert section for
operation details
When the switch
wired to the S1 for
Dry Contact Alert
activates, the
custom U contacts
T10+
will change state to
activate or shut off
whatever is wired to
those terminals
T10+
T10+
T10+