Honeywell Home T10 Product Data page 41

Smart thermostat with redlink 3.0
Hide thumbs Also See for T10:
Table of Contents

Advertisement

Firmware is occasionally updated at the factory or over the air. Some ISU settings may not be shown on models that lack the latest firmware.
ISU #
Heading
5100
Sensors
Discharge Temperature
Sensor Type
5110
Sensors
A-Coil Low Temperature
Cutoff
5120
Sensors
What Terminals are
Wired to the Floor
Temperature Sensor?
5150
Floor
Minimum Limit
Temperature
Limits
Maximum Limit
5160
Floor economy
Floor economy mode
mode
Freeze
5170
Freeze Protection
Protection
6000
Dry Contact
Select Dry Contact alerts Full Drain Pan Alert, Dirty
Alerts
6005
Custom Dry
Select Custom Dry
Contact alerts
Contact alerts
6050
Dry Contacts
What terminals are wired
to the Full Drain Pan
Alert dry contact?
6060
Dry Contacts
Full Drain Pan Alert dry
contact setup
6065
Dry Contacts
Full Drain Pan Alert dry
contact actions
6070
Dry Contacts
What terminals are wired
to the Dirty Filter Alert dry
contact?
6080
Dry Contacts
Dirty Filter Alert dry
contact setup
Table 9. Installer Setup (ISU). (Continued)
Question
Options
10K, 20K
Off, 5F to 65F (-15C to
18.5C)
None, EIM S1, EIM S2, EIM
S3, EIM S4
Minimum Limit = 40F-89F
(4.5C to 31.5C)
Maximum Limit = 50F-99F
(10.0C to 37.0C)
Yes or no
Off, 40°F-50°F (4.5°C to
10°C)
(Off only available for non-
radiant systems)
Filter Alert, Water Leak
Alert, System Shutdown
Alert, Service Needed Alert,
Fan Failure Alert
Custom Alert 1, Custom
Alert 2, Custom Alert 3,
Custom Alert 4
None, EIM S1, EIM S2, EIM
S3, EIM S4
Normally open, normally
closed
System shutdown (select or
de-select)
None, EIM S1, EIM S2,
EIM S3, EIM S4
Normally open,
normally closed
Contingent
previous
EIM
setting?
needed?
5000 has
No
Discharge
Sensor
selected
At least 1 cool
No
stage
1055 set to
Yes
"Wired"
No
ISU 2230 =
No
Air & Floor
5000 has Floor
No
Sensor
selected
Cannot be
below
minimum
No
setting in 5150
(if used).
Yes
Yes
6000 has full
Yes
drain pan
selected
6000 has full
Yes
drain pan
selected
6000 has full
Yes
drain pan
selected
6000 has Dirty
Yes
Filter Alert
selected
Yes
37
T10, T10+
or both
Notes
T10+
T10+
T10+
If an EIM is not
used this ISU isn't
shown and sensor
wires to S & S at
UWP
T10+
Top range affected
by Maximum limit
setting
T10+
Bottom range
affected by
Minimum limit
setting
T10+
If enabled, Low
Floor Temperature
Limit (ISU 5150) will
be disabled during
Away and Sleep
period. This ISU is
only displayed if
Temperature
Control Mode (ISU
2230) is set to AF
mode.
The thermostat
operates the heat
whenever the room
temperature falls
below that limit,
even when the
system is set to off.
Default setting is Off
T10+
(disabled) for non-
radiant systems and
40°F (4.5°C) for
radiant systems.
Freeze protection
temperature cannot
be set above ISU
5150 minimum
setting.
T10+
See Dry Contact
alert section for
operation details
T10+
T10+
T10+
See Dry Contact
T10+
alert section for
operation details
T10+
T10+
33-00462—05