Fault 65: Speed Stall—CRM 1
Note:
When any individual cutting reel motor is shut off due to a fault, the TEC-5002 shuts off the other 4
cutting reel motors.
Note:
If multiple machine faults are reported within a few seconds, troubleshooting should begin with the
first cutting reel motor to report a fault.
Note:
This fault can occur during heavy cutting conditions or as a result of a cutting unit malfunction. Ask the
machine operator for information regarding cutting conditions when the fault occurred.
InfoCenter Display:
Fault Description
The cutting reel motor on cutting unit 1 stalled.
Circuit Description
All 5 cutting reel motors and the motor/generator are linked on the 48 Vdc CAN bus circuit.
Conditions for Setting the Fault
If the cutting reel motor is active, yet remains at 0 rpm for more than 3 seconds, the fault is reported.
Note:
Check for fault 70 (High Temp Warning—CRM 1), as an overheated cutting reel motor or a cutting reel
motor stall could be a contributing factor to a stall speed fault.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
Step 2: Check cutting unit 1 for any debris clogging the reel.
WARNING
Contact with the cutting reels or other moving parts can result in personal injury.
•
Keep fingers, hands, and clothing away from the cutting reels or other moving parts.
•
Never attempt to turn the cutting reels by hand while the engine is running.
1.
Go to
Preparing for Troubleshooting and/or Testing (page 22)
_____FAULT
#65_____
Stall Speed
Clearing Faults from the InfoCenter (page
Returning the Machine to Service (page 22)
226
1
and follow the steps listed.
and follow the steps listed.