Toro Reelmaster 5010-H Diagnostic Manual page 160

Hide thumbs Also See for Reelmaster 5010-H:
Table of Contents

Advertisement

1. InfoCenter retaining ring
3.
Lift the InfoCenter out of the control arm.
4.
Insert the replacement InfoCenter into the control arm.
5.
Secure the InfoCenter with the retaining ring.
6.
Connect seat harness connector P52 to the InfoCenter.
Step 7: Use Toro DIAG to program the InfoCenter.
1.
Connect a PC with Toro DIAG software to the machine via a Toro DIAG Cable (Part No. 115-1944). Refer
to
Toro DIAG - Quick Start (page
2.
Use the Toro DIAG software to reprogram the machine in accordance with Toro DIAG User's Guide. The
replacement InfoCenter is programmed during the reprogramming of the machine.
3.
Disconnect the Toro DIAG cable from the machine.
4.
Go to
Returning the Machine to Service (page 22)
Figure 96
24).
and follow the steps listed.
160
g032844