Fault 62: M/G Fault Latch—Phase Over
Current
InfoCenter Display:
Fault Description
The over-current hardware protection on the phase current trips when the current limit is exceeded.
Circuit Description
The motor/generator is a 48 Vdc, air cooled, brushless, permanent magnet device. The motor/generator
has its own controller.
Conditions for Setting the Fault
The motor/generator controller senses excessive current draw through the motor/generator or the controller
itself.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Go to Step 2.
_____FAULT
#62_____
Fault Latch - Phase OC
Clearing Faults from the InfoCenter (page
Returning the Machine to Service (page 22)
219
21).
and follow the steps listed.