Step 4: Remove the controller from the motor/generator.
Remove the controller from the motor/generator. Refer to Chapter 5 of the 5010-H Service Manual.
Step 5: Inspect the wiring between the motor/generator and the
controller.
The motor/generator and the controller each have cabling that connects to the other component. Inspect the
wiring between the controller and the motor/generator.
Pass
The wiring between the controller and the motor/generator passed inspection. Go to Step 6.
Fail
The wiring between the controller and the motor/generator did not pass inspection. Only repair
wiring that has worn insulation or a recessed connector pin. Replace all components that have
damaged, burned, or broken wiring. Go to
the steps listed.
Step 6: Replace the motor/generator controller.
Install a replacement controller onto the existing motor/generator. Refer to Chapter 5 of the 5010-H Service
Manual and follow the steps listed.
Step 7: Install the motor/generator assembly.
Refer to Chapter 5 of the 5010-H Service Manual and follow the steps listed.
Step 8: Use Toro DIAG to program the motor/generator.
1.
Remove the access panel from the outer cover of the control arm.
2.
Connect a PC with Toro DIAG software to the machine via a Toro DIAG Cable (Part No. 115-1944). Refer
to
Toro DIAG - Quick Start (page
3.
Use the Toro DIAG software to reprogram the machine in accordance with Toro DIAG User's Guide. The
replacement motor/generator is programmed during the reprogramming of the machine.
4.
Disconnect the Toro DIAG cable from the machine.
5.
Install the access panel onto the outer cover of the control arm.
6.
Go to
Returning the Machine to Service (page 22)
Returning the Machine to Service (page 22)
24).
and follow the steps listed.