Fault 32: Unknown Cutting Unit Fault

InfoCenter Display:
Fault Description
An unknown cutting unit/cutting reel motor fault has occurred. A fault reference table error exists within the
TEC-5002 software.
Circuit Description
The reference tables are stored in the non-volatile memory of the TEC-5002.
Conditions for Setting the Fault
Only an error in the software can cause the TEC-5002 to set this fault.
Recommended Service Actions
Step 1: Verify that the fault repeats.
1.
Clear the system faults from the InfoCenter. Refer to
2.
Operate the machine.
Pass
The fault did not repeat. Go to
Note:
If the fault does not repeat, an isolated event has occurred.
Fail
The fault repeated. Contact the Toro Technical Assistance Center for additional guidance.
Note:
You must fix this software fault; accomplish the TEC-5002 software repair with direct
assistance from Toro.
_____FAULT
#32_____
Unknown CU Fault
Clearing Faults from the InfoCenter (page
Returning the Machine to Service (page 22)
112
21).
and follow the steps listed.