Perform resets of the unit as follows (see figure 8):
Figure 8.
Mode Activation
Hold in the recessed rear panel
Reset button while applying power
to the unit.
NOTE:
Do not operate with the default firmware loaded by this reset. Use it only to load the most current firmware
to the device.
Hold in the Reset button until the
Power LED blinks three times (once
at 3 seconds, again at 6 seconds,
again at 9 seconds). Then, release
and press the Reset button again
within 1 second*.
NOTES:
*For Full Factory Reset, nothing happens if the momentary press does not occur within 1 second.
The factory configured passwords for all accounts on this device have been set to the device serial number.
In the event of a complete system reset, the passwords convert to the default, which is extron (see
Passwords Panel

Configuration

NOTE: Transmitters and receivers can be configured via PCS (see

EDID

The FOX3 T 101 uses EDID Minder, which ensures that a source device connected to
the transmitter input continuously sees the EDID of a sink device, even if the sink is not
physically connected. By default, the EDID is set to 1080p @ 60 Hz with 2-channel audio.
There is one slot to upload custom EDID to the device.
Use PCS to upload EDID to the device (see the FOX3 T 101 and FOX3 R 101 Help File).
Run Factory Boot Code
RESET
Press and hold
the Reset button.
Full Factory Reset
RESET
Press and hold
for 9 seconds.
Resets
Reset Modes
Result
The device reverts to the factory default
firmware for a single power cycle.
Performs a complete reset to factory
defaults (except the firmware).
Clears port configurations.
Resets all IP options.
Clears all user settings.
Clears all passwords.
Clears all files from the unit.
The Reset LED on the rear panel
of the unit flashes four times in
succession.
on page 30 to change a password).
Software
(see page 19) and SIS commands (see
on page 12). Product help files are available in PCS when a device is connected or
an offline device is selected.
FOX3 T 101 Transmitter and FOX3 R 101 Receiver • Installation and Operation
RESET
Apply power
to the FOX3.
Release, then immediately
press and release again.
Reset LED ashes three
Reset LED ashes, then goes off.
times.
RESET
RESET
Purpose and Notes
Revert to the factory default
firmware for a single power cycle
if incompatibility issues arise with
user-loaded firmware. All user files
and settings are maintained.
Start over with default configuration
and uploading, and also to replace
events.
Equivalent to SIS command ZQQQ
(see
SIS Configuration and Control
Release Reset button.
Resets
on page 17).