Simple Instruction Set Control; Host-To-Unit Instructions; Device-Initiated Power-Up Message; Error Responses - Extron electronics FOX3 101 User Manual

Fiber optic hdmi transmitter and receiver
Hide thumbs Also See for FOX3 101:
Table of Contents

Advertisement

Using verbose mode
SSH connections to a FOX3 device can be used to monitor changes that occur on the
device, such as SIS commands from other SSH sockets or a serial port. For an SSH
session to receive change notices from the device, the SSH session must be in verbose
mode 1 or mode 3 (see the SIS command

Simple Instruction Set Control

Host-to-Unit Instructions

SIS commands consist of one or more characters per field. No special characters are
required to begin or end a command character sequence. When a command is valid, the
FOX3 101 device executes the command and sends a response to the host device. All
responses from the FOX3 101 device to the host end with a carriage return and a line feed
(CR/LF =
more characters.

Device-Initiated Power-Up Message

When the device completes start-up, it issues the following message to the host:
© Copyright 20yy, Extron Electronics FOX3 T (R) 101 MM (SM), Vx.xx, 60-nnnn-nn

Error Responses

When the FOX3 101 device receives a valid SIS command, it executes the command
and sends a response to the host device. If the FOX3 101 device is unable to execute the
command because the command is invalid or it contains invalid parameters, the FOX3 101
device returns an error response to the host. The error response codes are:
NOTES:
The FOX3 device is shipped password-protected. The factory configured
passwords for all accounts on this device have been set to the device serial
number.
In the event of a complete system reset, the password converts to the default,
which is extron. New passwords must be configured to secure the device.
On password-protected connections, there are two levels of protection:
administrator and user. Administrators have full access to all capabilities and
editing functions. Users can view all settings with the exception of passwords.
]
), which signals the end of the response character string. A string is one or
20yy is the year of the copyright.
Vx.xx is the firmware version number.
60-nnnn-nn is the part number.
E10 — Invalid command
E11 — Invalid preset number
E13 — Invalid parameter
E14 — Invalid for this configuration
E17 — Invalid command for signal type
E18 — System or command timed out
E21 — Invalid room number
FOX3 T 101 Transmitter and FOX3 R 101 Receiver • SIS Configuration and Control
Verbose mode
on page 17).
E22 — Busy
E24 — Privilege violation
E25 — Device not present
E26 — Maximum number of connections
exceeded
E28 — Bad file name or file not found
13