Table 9-3 Event Log Entries Unique To The Equipment - Hitachi HF-W6500 Instruction Manual

Industrial computer
Hide thumbs Also See for HF-W6500:
Table of Contents

Advertisement

9. TROUBLE SHOOTING
Table 9-3 lists event log entries unique to the equipment. No.1 through 18 and No.21 through
33 are collected in the system log, and No.19 and 20 are collected in the application log.

Table 9-3 Event Log Entries Unique to the Equipment (1/3)

Event
No.
Source
ID
1
257 HFWRAS_SYS
2
259 HFWRAS_SYS
260 HFWRAS_SYS Information Remote shutdown request
3
261 HFWRAS_SYS Information Revolutions of fan at
4
263 HFWRAS_SYS Information Temperature returned to
5
6
265 HFWRAS_SYS
7
268 HFWRAS_SYS
8
270 HFWRAS_SYS Information Used hours on the drive of
9
279 HFWRAS_SYS
10
280 HFWRAS_SYS Information Revolutions of system fan1
11
281 HFWRAS_SYS
12
282 HFWRAS_SYS Information Revolutions of system fan2
13
519 HFWRAS_SYS
Type
Description
Error
Revolutions of fan at
power supply deteriorated
remarkably.
The temperature
Warning
exceeded prescribed value.
occurred.
power supply returned to
normal value.
prescribed value.
Warning
A failure may be imminent
on the drive of the drive
bay%1 (%2).
Error
The computer was shut
down because temperature
became dangerous.
the drive bay%1 exceeded
prescribed value.
Error
Revolutions of system fan1
deteriorated remarkably.
returned to normal value.
Error
Revolutions of system fan2
deteriorated remarkably.
returned to normal value.
Error
A failure occurred in the
RAS MCU.
9-22
Action
Read the description of fan failure in
"9.2.2 (1)" and take an action
accordingly.
Read the description of abnormal
temperature in "9.2.2 (1)" and take action
accordingly.
No handling.
No handling.
No handling.
We recommend you back up the data and
replace the drive.
Read the description of abnormal
temperature in "9.2.2 (1)" and take action
accordingly.
We recommend you back up the data and
replace the drive.
Read the description of fan failure in
"9.2.2 (1)" and take an action
accordingly.
No handling.
Read the description of fan failure in
"9.2.2 (1)" and take an action
accordingly.
No handling.
The RAS MCU might be malfunctioning.
Contact your system administrator or
maintenance personnel.

Advertisement

Table of Contents
loading

This manual is also suitable for:

60