5. SPECIFICATION
(2) List of external control I/O signals
Signal name
CPU side
PSDOWN_1
40 VDC 0.1A
Contact spec
PSDOWN_2
40 VDC 0.1A
CPUSTOP_1
Contact spec
CPUSTOP_2
40 VDC 0.1A
MCALL_1
Contact spec
MCALL_2
GENDO0_1
40 VDC 0.1A
Contact spec
GENDO0_2
40 VDC 0.1A
GENDO1_1
Contact spec
GENDO1_2
40 VDC 0.1A
GENDO2_1
Contact spec
GENDO2_2
40 VDC 0.1A
WDTTO_1
Contact spec
WDTTO_2

Table 5-21 List of external control I/O signals (1/2)

Connection diagram
Terminal
User side
No.
Fuse
5
Load
Surge Sup
18
Fuse
23
Load
Surge Sup
9
Fuse
1
Load
Surge Sup
14
Fuse
2
Load
Surge Sup
15
Fuse
3
Load
Surge Sup
16
Fuse
24
Load
Surge Sup
10
Fuse
4
Load
Surge Sup
17
Meaning
Activated when the OS is
shut down (standby or the
main power is off) or when
power is not supplied to the
equipment.
Activated when the OS,
application, device driver, or
the like cannot run properly
due to an abnormally high
system load or has crashed.
This is a maintenance request
signal. This contact is
activated when the
temperature, the fan status or
one side of mirrored
disks (B model, T model
only)
is abnormal.
These are general-purpose
contact output signals. A user
can assign a function to each
one of the contacts GENDO0
through GENDO2.
Activated when a timeout is
detected by the watchdog
timer. A timeout is also
detected when the OS is shut
down (standby or the main
power is off) or when power
is not supplied to the
equipment.
5-24
HJ-F6560-17
HJ-F6560-18
B contact
A contact
specifications
specifications
When the power is
When the power is
off
Contact closed
Contact open
(B contact)
(A contact)
When the power is
When the power is
off
Contact closed
Contact open
When the power is
When the power is
off
Contact closed
Contact open
(B contact)
(A contact)
When the CPU is
When the CPU is
stopped
stopped
Contact closed
Contact open
When the power is
When the power is
off
Contact open
Contact open
(A contact)
(A contact)
When maintenance
When maintenance
is requested
is requested
Contact closed
Contact closed
When the power is
When the power is
off
Contact open
Contact open
(A contact)
(A contact)
User-defined
User-defined
When the power is
When the power is
off
Contact open
Contact open
(A contact)
(A contact)
User-defined
User-defined
When the power is
When the power is
off
Contact open
Contact open
(A contact)
(A contact)
User-defined
User-defined
When the power is
When the power is
off
Contact Closed
Contact open
(B contact)
(A contact)
When watchdog
When watchdog
timer timeout
timer timeout
occurs or
occurs or
when CPU power
when CPU power
is off
is off
Contact closed
Contact open
off
off
off
off
off
off
off
off