9. TROUBLE SHOOTING
Table 9-3 Event Log Entries Unique to the Equipment (3/3)
Event
No.
Source
ID
25
2003
HFWRAS_SYS
26
2004
HFWRAS_SYS
27
2009
HFWRAS_SYS
28
2011 HFWRAS_SYS
29
2012 HFWRAS_SYS
2019 HFWRAS_SYS
30
3000 HTsfRAID_SYS
31
3001 HTsfRAID_SYS
32
3010 HTsfRAID_SYS
33
Type
Description
Error
RAS could not get the
RAID status. RAID status
is UNKNOWN.
Information RAID status was revealed.
Information
The drive on the drive
bay%1 is OFFLINE
because of manual
operation.
Information Rebuilding was completed.
But unreadable sectors
were detected on the
source drive (Drive
bay%1). (Media error)
Error
Rebuilding failed due to
error on the destination
drive (Drive bay%1).
Information Media error is occurred on
RAID.
Information RAID status changed.
(ARRAY = %1, DRIVE1
= %2, DRIVE2 = %3)
Information Rebuild process was
stopped.
Reason: %1
Error
Service internal error.
Reason: %1
9-24
Action
Contact the system administrator or
maintenance personnel.
No handling
No handling
Read the description of "10.4.2" and
take action accordingly.
Read the description of "10.2.2" and
build a RAID again.
Read the description of HF-W6500
Model 60 RAS FEATURES
MANUAL(WIN-63-0100) "2.8.2" and
take action accordingly.
No action is required.
See section 10.4.3 and take appropriate
action. If section 10.4.3 does not have
details for the code, contact the system
administrator or maintenance personnel.
Contact the system administrator or
maintenance personnel.

Advertisement

Table of Contents
loading

This manual is also suitable for:

60

Table of Contents