Chapter 2 Preparations

Installing tertiary riser card (low-profile) N8116-55

By fitting this riser card, you can fix a half-length or low profile PCI board.
To install the components, follow these steps.
1.
See steps 1 to 6 in Chapter 2 (1.2 Overview of Installation and Removal) for preparations.
2.
Install optional secondary riser card.
(1)
Confirm that positions of secondary riser card and the arrow mark on the power cage are correct
and keep the riser card as horizontal state.
(2)
In order to connect the edge connector to mother board connector, plug in the secondary riser card.
Stick the terminal part of riser card and slot part on the mother board together and insert them in
with certainly.
3.
See Chapter 2 (1.26 Installing Top Cover) to attach the top cover of the server.
4.
Please see Chapter 2 (2 Installation and Connection) in this manual to conduct installation and connection,
and turn the power supply ON.
Important
The surface becomes hot after use so to avoid burns please allow the drive
and internal parts of the system to cool before touching.
Note
In order to prevent the damage to electronic components, please start to install the
system after conducting the appropriate anti-static treatment. There is a possibility
of causing electrostatic discharge if appropriate grounding wire treatment is not
conducted.
Note
In order to prevent damage of the system due to improper cooling or elevated
temperature, please do not activate the server or enclosure without implementing
any of component or blank on all of drive bays and device bays.
Express5800/R120h-1M User's Guide
1. Installing Internal Optional Devices
89