Danfoss FC 302 Instruction Manual page 69

Hide thumbs Also See for FC 302:
Table of Contents

Advertisement

FC 300 Instruction Manual
LED indication
Warning
Alarm
Trip locked
Alarm Word Extended Status Word
Bit
Hex
0
00000001
1
00000002
2
00000004
3
00000008
4
00000010
5
00000020
6
00000040
7
00000080
8
00000100
9
00000200
10
00000400
11
00000800
12
00001000
13
00002000
14
00004000
15
00008000
16
00010000
17
00020000
18
00040000
19
00080000
20
00100000
21
00200000
22
00400000
23
00800000
24
01000000
25
02000000
26
04000000
27
08000000
28
10000000
29
20000000
30
40000000
31
80000000
Troubleshooting
yellow
flashing red
yellow and red
Dec
AlarmWord
1
Brale Check
2
Pwr. Card Temp
4
Earth Fault
8
Ctrl.Card Temp
16
Ctrl. Word TO
32
Over Current
64
Torque Limit
128
Motor Th Over
256
Motor ETR Over
512
Inverter Overld.
1024
DC under Volt
2048
DC over Volt
4096
Short Circuit
8192
Inrush Fault
16384
Mains ph. Loss
32768
AMA Not OK
65536
Live Zero Error
131072
Internal Fault
262144
Brake Overload
524288
U phase Loss
1048576
V phase Loss
2097152
W phase Loss
4194304
Fieldbus Fault
8388608
24 V Supply Low
16777216
Mains Failure
33554432
1.8V Supply Low
67108864
Brake Resistor
134217728
Brake IGBT
268435456
Option Change
536870912
Drive Initialised
1073741824
Safe Stop
2147483648
Mech. brake low
MG.33.A4.22 - VLT is a registered Danfoss trademark
WarningWord
Brale Check
Pwr. Card Temp
Earth Fault
Ctrl.Card Temp
Ctrl. Word TO
Over Current
Torque Limit
Motor Th Over
Motor ETR Over
Inverter Overld.
DC under Volt
DC over Volt
DC Voltage Low
DC Voltage High
Mains ph. Loss
No Motor
Live Zero Error
10V Low
Brake Overload
Brake Resistor
Brake IGBT
Speed Limit
Fieldbus Fauld
24V Supply Low
Mains Failure
Current Limit
Low Temp
Voltage Limit
Unused
Unused
Unused
Warning Word 2
(Extended Status Word)
ExtendedStatusWord
Ramping
AMA Running
Start CW/CCW
Slow Down
Catch Up
Feedback High
Feedback Low
Output Current High
Output Current Low
Output Freq High
Output Freq Low
Brake Check OK
Braking Max
Braking
Out of Speed Range
OVC Active
69

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FC 302 and is the answer not in the manual?

Questions and answers

Ishtiaq Ahmed
March 14, 2025

Alarm-88 description required & remedy?

1 comments:
Mr. Anderson
May 14, 2025

Description: Alarm 88 on the Danfoss FC 302 indicates "Option Detection." It occurs when a change in the option layout is detected while Parameter 14-89 (Option Detection) is set to [0] Frozen configuration.

Remedy:
1. Enable option layout changes by setting Parameter 14-89 to allow changes.
2. Alternatively, restore the correct option configuration.