Top section
shows up to 2 measurements
in normal operating status.
The top line in the
Middle section
5 measurements with related units, regardless of
status (except in the case of alarm/warning).
Bottom section
always shows the state of the
adjustable frequency drive in Status mode.
The Active Set-up (selected as the Active Set-up in par. 0-10) is shown. When programming another Set-up
other than the Active Set-up, the number of the programmed Set-up appears to the right.
Display Contrast Adjustment
Press [status] and [ ] for darker display
Press [status] and [ ] for brighter display
Most FC 300 parameter set-ups can be changed immediately via the control panel, unless a password
has been created via par. 0-60 Main Menu Password or via par. 0-65 Quick Menu Password.
LEDs:
If certain threshold values are exceeded, the alarm and/or warning LED light(s) up. A
status and alarm text appear on the control panel.
The on LED is activated when the adjustable frequency drive receives line voltage or via a DC bus
terminal or 24 V external supply. At the same time, the back light is on.
Green LED/On: Control section is working.
Yellow LED/Warn.: Indicates a warning.
Flashing Red LED/Alarm: Indicates an alarm.
LCP keys
The control keys are divided into functions. The
keys below the display and LEDS are used for
parameter Set-up, including choice of display
indication during normal operation.
[Status]
indicates the status of the adjustable frequency drive and/or the motor. You can
choose between 3 different readouts by pressing the [Status] key: