Mode In Progress - Pentair E-Box MAESTRO Lite Installation And Operation Manual

Table of Contents

Advertisement

Installation and Operation Guide Version E-Box MAESTRO Lite - Programming
CAUTION
A RedOx too high can damage elements of the basin!
A RedOx too low can be dangerous for hygiene!
ü ensure that:
ü the spigot has been removed from the RedOx probe (see Probe Unit [
ü the RedOx probe is not clogged (see Cleaning the pH or RedOx probe [
• manual regulation: Add disinfectant (chlorine, bromine, active oxygen, etc.) to the
desired value.
• automatic regulation: Check the proper functioning of the equipment with your pool
owner.
5.2.6

Mode in progress

5.2.6.1
Alarm mode
This mode is used to modify the setpoint value of:
• the high pH alarm (factory pre-set to 7.9);
• low pH alarm (factory pre-set to 6.7);
• the high conductivity alarm (factory pre-adjusted to 1200 μS);
• the low conductivity alarm (factory pre-adjusted to 50 μS);
• the RedOx high alarm (factory pre-adjusted to 800 mV);
• redOx low alarm (factory pre-adjusted to 500 mV).
Alarm setpoint modification
Info
All these values remain stored when changing batteries.
Info
To reset all device defaults, press and hold (4 s) "reset" with a desktop paper clip on the
back of the Inner Display. The operation is validated by a long beep.
64 / 90
The Alarm (Alarm mode [
(Calibration mode [
Page 66]) correspond to the position of
the switch on the back of the Inner Display.
The Radio mode means (Radio mode [
radio is learning a new element on the MAESTRO network.
Ref. SB-CU-IMP-062EBLA / A - 11.05.2023
Page 64]) and Calibration modes
Page 70]) that the
Page 20])
Page 79])

Advertisement

Table of Contents
loading

Table of Contents