c. To open the release lever, press the latch.
d. Pull the release lever to disengage the drive from the backplane, and then slide the drive out of the bay.
Remove an SFF drive:
a. Determine the status of the drive from the SFF LEDs (see Drive LEDs).
b. Wait until the icon in the Do Not Remove button stops flashing and is no longer illuminated.
c. Press the Do Not Remove button to open the release lever.
d. Pull the release lever to disengage the drive from the backplane, and then slide the drive out of the bay.
To replace the component, reverse the removal procedure.
Removing and replacing a hot-plug drive from drive cage 2
Removing and replacing a hot-plug drive from
Procedure
Procedure
1. Back up all server data.
2. Extend the server from the rack .
3. Open drive cage 2.
drive cage 2
HPE Apollo 4200 Gen10 Plus Server Maintenance and Service Guide
27