S
W
UPER
ORKSTATION 7034A-T/7034A-i Manual
6-2
Front Control Panel
The front control panel must be connected to the JF1 connector on the
serverboard to provide you with system status and alarm indications. A ribbon
cable has bundled these wires together to simplify this connection. Connect the
cable from JF1 on the serverboard (making sure the red wire plugs into pin 1) to
the appropriate connector on the front control panel PCB (printed circuit board).
Pull all excess cabling over to the control panel side of the chassis. The LEDs
inform you of system status - see Figure 6-1 for details.
Refer to Figure 6-2 for the features included on the front of the chassis and
to Figure 6-3 for the features on the rear of the chassis. See Chapter 5 for
details on JF1.
P o w e r
HDD
NIC
Overheat/Fan
Fail
Figure 6-1.
Front Control Panel LEDs
Indicates power is being supplied to the system.
Indicates SATA/IDE/CD-ROM drive activity.
Indicates network activity on the GLAN port.
Indicates an overheat condition or a fan failure.
Flashing: fan failure
On (not flashing): overheat
Off: normal
6-2