  • Page 1 SuperWorkstation SYS-530T-I USER’S MANUAL Revision 1.0...
  • Page 2 State of California, USA. The State of California, County of Santa Clara shall be the exclusive venue for the resolution of any such disputes. Supermicro's total liability for all claims will not exceed the price paid for the hardware product.
  • Page 3 If you have any questions, please contact our support team at: support@supermicro.com This manual may be periodically updated without notice. Please check the Supermicro website for possible updates to the manual revision level. Secure Data Deletion A secure data deletion tool designed to fully erase all data from storage devices can be found on our website: https://www.supermicro.com/about/policies/disclaimer.cfm?url=/wdl/utility/...
  • Page 4: Table Of Contents

    Contents Contents Contacting Supermicro ......................7 Chapter 1 Introduction 1.1 Overview ..........................8 1.2 System Features ........................9 Front View ...........................9 Control Panel .........................10 Rear View ..........................11 1.3 System Block Diagram .......................12 1.4 Motherboard Layout ......................13 Quick Reference Table ......................15 Chapter 2 Installation 2.1 Overview ..........................17...
  • Page 5 Contents 3.7 Storage Drives ........................32 Installing Components in the 5.25" Drive Bays .............34 Removing the Empty Drive Bay ..................34 Adding a DVD-ROM Drive (optional)................34 System Cooling .........................35 Replacing the System Fan ....................35 Power Supply ........................36 Chapter 4 Motherboard Connections 4.1 Power Connections ......................37 4.2 Headers and Connectors ....................38 Front Control Panel LEDs .....................41 4.3 Rear I/O Ports ........................44...
  • Page 6 7.9 Reporting an Issue ......................70 Technical Support Procedures ..................70 Returning Merchandise for Service ...................70 Vendor Support Filing System ..................71 7.10 Feedback ...........................71 7.11 Contacting Supermicro .......................72 Appendix A Standardized Warning Statements for AC Systems Appendix B System Specifications BSMI/RoHS ..........................95...
  • Page 7: Contacting Supermicro

    Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V. Het Sterrenbeeld 28, 5215 ML...
  • Page 8: Chapter 1 Introduction

    Mini-tower 14.3 x 7.3 x 16.8in. / 362 x 184 x 425mm (HxWxD) Notes: A Quick Reference Guide can be found on the product page of the Supermicro website. The following safety models associated with the SYS-530T-I have been certified as compliant...
  • Page 9: System Features

    Chapter 1: Introduction 1.2 System Features The following views of the system display the main features. Refer to Appendix B for additional specifications. Front View Control Panel Figure 1-1. Front View SYS-530T-I System Features: Front Feature Description Control Panel Front control panel (see Control Panel section for details)
  • Page 10: Control Panel

    Chapter 1: Introduction Control Panel USB Port USB Port Power LED Information LED NIC (LAN1) LED Figure 1-2. Control Panel Control Panel Features Feature Description The main power switch is used to apply or remove power from the power supply to the workstation.
  • Page 11: Rear View

    Chapter 1: Introduction Rear View Power COM Port IPMI LAN Port USB Ports USB Ports GbE LAN Ports VGA Port Reset Button PCIe Slots Figure 1-3. System: Rear View System Features: Rear Feature Description Power One 400W PS/2 power supply, 80 Plus Gold PS/2 level COM Port One COM port USB Ports...
  • Page 12: System Block Diagram

    Chapter 1: Introduction 1.3 System Block Diagram The block diagram below shows the connections and relationships between the subsystems and major components of the overall system. IMVP 8 6 PHASE for Vcore #B-1 #B-0 PCI-E x8 PCIe Gen4 x8 #A-1 #0-7 SLOT6 ( in x16 )
  • Page 13: Motherboard Layout

    Chapter 1: Introduction 1.4 Motherboard Layout Below is a layout of the X12STL-F motherboard with jumper, connector, and LED locations shown. See the table on the following page for descriptions. For detailed descriptions, pinout information, and jumper settings, refer to Chapter 4 or the Motherboard Manual.
  • Page 14 Chapter 1: Introduction Notes: • " " indicates the location of Pin 1. • Jumpers/LED indicators not indicated are used for testing only. • Use only the correct type of onboard CMOS battery as specified by the manufacturer. Do not install the onboard battery upside down to avoid possible explosion.
  • Page 15: Quick Reference Table

    Chapter 1: Introduction Quick Reference Table Jumper Description Default Setting JBT1 CMOS clear Open (Normal) JPG1 VGA Enable/Disable Pins 1-2 (Enabled) JPME2 Manufacturing mode Pins 1-2 (Normal) Pins 1-2 PCH (Normal) JVRM1/JVRM2 VRM SMB clock (to BMC or PCH) Pins 2-3 BMC (Normal) JWD1 Watchdog timer Pins 1-2 (Reset)
  • Page 16 Chapter 1: Introduction Description Status Green: Indicates Speed BMC LAN LEDs BMC LAN Ports LEDs Amber: Indicates Activity Green (right): Indicates Activity LAN1 & LAN2 LEDs Ethernet Ports LEDs Link LED (left): Indicates Speed LED1 Unit Identifier LED Solid Blue: Unit Identified LED3 M.2 Activity LED Blinking Green: Device Working...
  • Page 17: Chapter 2 Installation

    Chapter 2: Installation Chapter 2 Installation 2.1 Overview This chapter provides advice setting up your system. If your system is not already fully integrated with processors, system memory etc., refer to Chapter 4 for details on installing those specific components. Caution: Electrostatic Discharge (ESD) can damage electronic components.
  • Page 18: Chapter 3 Maintenance And Component Installation

    Chapter 3: Maintenance and Component Installation Chapter 3 Maintenance and Component Installation This chapter provides instructions on installing and replacing main system components. To prevent compatibility issues, only use components that match the specifications and/or part numbers given. Installation or replacement of most components requires that power first be removed from the system.
  • Page 19: Accessing The System

    Chapter 3: Maintenance and Component Installation 3.2 Accessing the System The CSE-731I-404B chassis features a removable side cover for accessing the system need to remove power from the system as described in section 3.1, and front cover which allows easy access to the inside of the chassis. Top Cover Back Cover Side Cover...
  • Page 20 Chapter 3: Maintenance and Component Installation Removing the Side Cover 1. Remove power from the system as described in Section 3.1. 2. Slide the latch (A) to the handle (B) of the chassis cover. 3. Grasp the handle of the case cover and slide it toward the back of the case. 4.
  • Page 21 Chapter 3: Maintenance and Component Installation Opening the Front Cover The front bezel cover can be removed to install up to two peripheral drive bays at the front of the chassis. 1. Remove the front bezel from the chassis by lifting it upwards from the bottom, and then pulling out from the front of the chassis.
  • Page 22: Static-Sensitive Devices

    Chapter 3: Maintenance and Component Installation 3.3 Static-Sensitive Devices Electrostatic Discharge (ESD) can damage electronic components. To avoid damaging your motherboard, it is important to handle it very carefully. The following measures are generally sufficient to protect your equipment from ESD. Precautions •...
  • Page 23: Processor And Heatsink Installation

    Thermal grease is pre-applied on a new heatsink. No additional thermal grease is needed. • Refer to the Supermicro website for updates on processor and memory support. • All graphics in this manual are for illustrations only. Your components may look different.
  • Page 24 Chapter 3: Maintenance and Component Installation 2. Gently lift the load lever to open the load plate. Remove the plastic protective cover. Do not touch the CPU socket contacts. 3. Locate the triangle on the CPU and CPU socket, which indicates the location of Pin 1. Holding the CPU by the edges with your thumb and index finger, align the triangle on the CPU with the triangle on the socket.
  • Page 25 Chapter 3: Maintenance and Component Installation 5. Close the load plate, then gently push down the load lever into its locking position. CPU properly installed Load lever locked into place Note: You can only install the CPU in one direction. Make sure it is properly inserted into the socket before closing the load plate.
  • Page 26: Installing The Cpu Heatsink

    Chapter 3: Maintenance and Component Installation Installing the CPU Heatsink Do not apply thermal grease to the heatsink or the CPU--the required amount has already been applied. 1. Remove the power cord from the system. 2. Place the heatsink on top of the CPU so that the four mounting screws on the heatsink are aligned with holes on the socket.
  • Page 27: Removing The Heatsink

    Chapter 3: Maintenance and Component Installation Removing the Heatsink Note: We do not recommend that the CPU or the heatsink be removed. However, if you must remove the heatsink, follow the instructions below to avoid damage. 1. Remove power from the system as described in Section 3.1. 2.
  • Page 28: Memory

    Note: Memory speed support depends on the processors used in the system. For validated memory, use our Product Resources page. Check the Supermicro website for possible updates to memory support. Memory Installation Sequence Insert the DIMM modules in the following order: DIMMB2, then DIMMA2, DIMMB1, DIMMA1.
  • Page 29 Chapter 3: Maintenance and Component Installation Recommended Population (Balanced) DIMMA1 DIMMB1 DIMMA2 DIMMB2 Total System Memory 16GB 16GB 32GB 16GB 16GB 32GB 16GB 16GB 16GB 16GB 64GB 32GB 32GB 64GB 32GB 32GB 32GB 32GB 128GB...
  • Page 30: Dimm Installation

    Chapter 3: Maintenance and Component Installation DIMM Installation 1. Insert the desired number of DIMMs into the slots based on the recommended DIMM population tables shown above. 2. Push the release tabs on both ends of the DIMM slot outwards to unlock it. 3.
  • Page 31: Motherboard Battery

    Chapter 3: Maintenance and Component Installation 3.6 Motherboard Battery The motherboard uses non-volatile memory to retain system information when system power is removed. This memory is powered by a lithium battery residing on the motherboard. Replacing the Battery Begin by removing power from the system as described in section 3.1.
  • Page 32: Storage Drives

    8. If necessary, use an additional (optional) screw to lock the middle position of each hard disk to fix the hard disk on the disk rack. Note: Enterprise level hard disk drives are recommended for use in Supermicro chassis and workstations. For information on recommended HDDs, visit the Supermicro website at...
  • Page 33 Chapter 3: Maintenance and Component Installation Cage (A) Hard drive rack (B) Figure 3-6. Rotating Hard Drive Rack Latch Figure 3-7. Install the Hard Drive in the Case...
  • Page 34: Installing Components In The 5.25" Drive Bays

    Chapter 3: Maintenance and Component Installation Installing Components in the 5.25" Drive Bays The SYS-530T-I has two 5.25" drive bays. Components such as an extra DVD-ROM drive can be installed into these 5.25" drive bays. Removing the Empty Drive Bay 1.
  • Page 35: System Cooling

    Chapter 3: Maintenance and Component Installation System Cooling The CSE-731I-404B includes a super quiet rear system fan that provides cooling for the chassis. No tools or screws are required to install the system fan. Under normal operation, the chassis fan and the power supply fan both run continuously. If the chassis fan fails, the system must be powered down before replacing it.
  • Page 36: Power Supply

    Chapter 3: Maintenance and Component Installation Power Supply The 530T-I chassis includes a 400W power supply. The power supply has the capability to automatically sense and operate with an input voltage of 100-240V AC. If it becomes necessary to replace the power supply, follow the instructions below. Replacing the Power Supply Begin by removing power from the system as described in section 3.1 and access the inside of the system as described in section 3.2.
  • Page 37: Chapter 4 Motherboard Connections

    Chapter 4: Motherboard Connections Chapter 4 Motherboard Connections This section describes the connections on the motherboard and provides pinout definitions. Note that depending on how the system is configured, not all connections are required. The LEDs on the motherboard are also described here. The motherboard layout indicating component locations may be found in Chapter 1.
  • Page 38: Headers And Connectors

    It allows the motherboard to deny access if the TPM associated with the hard drive is not installed in the system. Go to the following link for more information on the TPM: http://www.supermicro.com/manuals/other/TPM.pdf. Trusted Platform Module Header Pin Definitions...
  • Page 39 Chapter 4: Motherboard Connections 4-pin BMC External I C Header A system Management Bus header for IPMI 2.0 is located at JIPMB1. Connect the appropriate cable here to use the IPMB I C connection on your system. Refer to the table below for pin definitions.
  • Page 40 Chapter 4: Motherboard Connections Power SMB (I C) Header The Power System Management Bus (I C) connector (JPI C1) monitors the power supply, fan, and system temperatures. Refer to the table below for pin definitions. Power SMB Header Pin Definitions Pin# Definition Clock...
  • Page 41: Front Control Panel Leds

    These connectors are designed specifically for use with Supermicro chassis. See the figure below for the descriptions of the front control panel buttons and LED indicators.
  • Page 42 Chapter 4: Motherboard Connections Power Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins will power on/off the system. Refer to the table below for pin definitions. Power Button Pin Definitions (JF1) Pin# Definition Signal...
  • Page 43 Chapter 4: Motherboard Connections NIC1/NIC2 (LAN1/LAN2) The Network Interface Controller (NIC) LED connection for LAN port 1 is located on pins 11 and 12 of JF1, and LAN port 2 is on pins 9 and 10. Attach the NIC LED cables here to display network activity.
  • Page 44: Rear I/O Ports

    Chapter 4: Motherboard Connections 4.3 Rear I/O Ports Rear I/O Ports Description Description COM Port 1 USB5 (3.2 Gen1) USB0 (2.0) LAN1 USB1 (2.0) LAN2 Dedicated BMC LAN VGA Port USB4 (3.2 Gen1) UID Switch VGA Port A video (VGA) port is located next to LAN2 on the I/O back panel. Refer to the board layout below for the location.
  • Page 45 Chapter 4: Motherboard Connections LAN Ports Two Gigabit Ethernet ports (LAN1, LAN2) are located on the I/O back panel. In addition to the LAN ports, a dedicated BMC LAN is located next to the USB0/1 ports on the back panel. All these ports accept RJ45 cables.
  • Page 46 Press the switch again to turn off the LED indicator. Note: UID can also be triggered via BMC on the motherboard. For more information on BMC, please refer to the BMC User's Guide posted on our website at http://www.supermicro.com/ support/manuals/. UID LED...
  • Page 47: Jumper Settings

    Chapter 4: Motherboard Connections 4.4 Jumper Settings Connector Pins How Jumpers Work Jumper To modify the operation of the motherboard, jumpers can be used to choose between optional settings. Jumpers Setting create shorts between two pins to change the function of the connector.
  • Page 48 Chapter 4: Motherboard Connections Watchdog Watchdog (JWD1) is a system monitor that can reboot the system when a software application hangs. Close pins 1-2 to reset the system if an application hangs. Close pins 2-3 to generate a non-maskable interrupt (NMI) signal for the application that hangs. Refer to the table below for jumper settings.
  • Page 49: Led Indicators

    Chapter 4: Motherboard Connections 4.5 LED Indicators Onboard Power LED LED4 is the onboard Power LED. When this LED is on, the system is on. Turn off the system and unplug the power cord before removing or installing components. Refer to the table below for more information.
  • Page 50 Chapter 4: Motherboard Connections LAN LEDs Two LAN ports (LAN 1 and LAN 2) are located on the rear I/O panel of the motherboard. Each Ethernet LAN port has two LEDs. The green LED indicates activity, while the other Link LED may be green, amber, or off to indicate the speed of the connection.
  • Page 51: Storage Ports

    Note: For more information on the SATA HostRAID configuration, refer to the Intel SATA HostRAID user's guide posted at https://www.supermicro.com/support/manuals/. M.2 Slot This motherboard has one M.2 connector. M.2 was formerly known as Next Generation Form Factor (NGFF) and serves to replace mini PCIe.
  • Page 52: Chapter 5 Software

    USB/SATA DVD drive, or a USB flash drive, or the IPMI KVM console. 2. Retrieve the proper RST/RSTe driver. Go to the Supermicro web page for your motherboard and click on "Download the Latest Drivers and Utilities", select the proper driver, and copy it to a USB flash drive.
  • Page 53 Chapter 5: Software 4. During Windows Setup, continue to the dialog where you select the drives on which to install Windows. If the disk you want to use is not listed, click on “Load driver” link at the bottom left corner. Figure 5-2.
  • Page 54: Driver Installation

    The Supermicro website contains drivers and utilities for your system at https://www. supermicro.com/wdl/driver. Some of these must be installed, such as the chipset driver. After accessing the website, go into the CDR_Images (in the parent directory of the above link) and locate the ISO file for your motherboard. Download this file to a USB flash drive or a DVD.
  • Page 55: Superdoctor ® 5

    5.3 SuperDoctor ® The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interface for Windows and Linux operating systems. The program monitors such system health information as CPU temperature, system voltages, system power consumption, fan speed, and provides alerts via email or Simple Network Management Protocol (SNMP).
  • Page 56: Bmc

    This can be found on a sticker on the chassis and a sticker on the motherboard. The sticker also displays the BMC MAC address. If necessary, the password can be reset using the Supermicro IPMICFG tool. Figure 5-5. BMC Password Label The sticker can be found on the pull-out service tag at the front of the chassis.
  • Page 57: Chapter 6 Optional Components

    It enables the motherboard to deny access if the TPM associated with the hard drive is not installed in the system. Details and installation procedures are at: http://www.supermicro.com/manuals/other/TPM.pdf. • AOM-TPM-9670V •...
  • Page 58: Chapter 7 Troubleshooting And Support

    Chapter 7 Troubleshooting and Support 7.1 Information Resources Website A great deal of information is available on the Supermicro website, www.supermicro.com. Menu Icon Figure 7-1. Supermicro Website • Specifications for workstations and other hardware are available by clicking the menu icon, then selecting the Products option.
  • Page 59: Baseboard Management Controller (Bmc)

    Security Center for recent security notices Supermicro Phone and Addresses 7.2 Baseboard Management Controller (BMC) The system supports the Baseboard Management Controller (BMC). BMC is used to provide remote access, monitoring, and management. There are several BIOS settings that are related to BMC.
  • Page 60: Troubleshooting Procedures

    Chapter 7: Troubleshooting and Support 7.3 Troubleshooting Procedures Use the following procedures to troubleshoot your system. If you have followed all of the procedures below and still need assistance, refer to the Technical Support Procedures Returning Merchandise for Service section(s) in this chapter. Power down the system before changing any non-hot-swap hardware components.
  • Page 61: Losing The System Setup Configuration

    Also check the Control panel Overheat LED. • Adequate power supply: Make sure that the power supply provides adequate power to the system. Make sure that all power connectors are connected. Refer to the Supermicro website for the minimum power requirements. •...
  • Page 62 Chapter 7: Troubleshooting and Support • Use the minimum configuration for troubleshooting: Remove all unnecessary components (starting with add-on cards first), and use the minimum configuration (but with a CPU and a memory module installed) to identify the trouble areas. •...
  • Page 63: Crash Dump Using Bmc

    Chapter 7: Troubleshooting and Support 7.4 Crash Dump Using BMC In the event of a processor internal error (IERR) that crashes your system, you may want to provide information to support staff. You can download a crash dump of status information using BMC.
  • Page 64: Uefi Bios Recovery

    Warning: Do not upgrade the BIOS unless your system has a BIOS-related issue. Flashing the wrong BIOS can cause irreparable damage to the system. In no event shall Supermicro be liable for direct, indirect, special, incidental, or consequential damages arising from a BIOS update.
  • Page 65 USB device or a writable CD/DVD. Note 1: If you cannot locate the "Super.ROM" file in your drive disk, visit our website at www.supermicro.com to download the BIOS package. Extract the BIOS binary image into a USB flash device and rename it "Super.ROM" for the BIOS recovery use.
  • Page 66 Chapter 7: Troubleshooting and Support Note: At this point, you may decide if you want to start the BIOS recovery. If you decide to proceed with BIOS recovery, follow the procedures below. 4. When the screen as shown above displays, use the arrow keys to select the item "Proceed with flash update"...
  • Page 67 Chapter 7: Troubleshooting and Support 7. Press <Del> continuously during system boot to enter the BIOS Setup utility. From the top of the toolbar, select Boot to enter the submenu. From the submenu list, select Boot Option #1 as shown below. Then, set Boot Option #1 to [UEFI AP:UEFI: Built-in EFI Shell]. Press <F4>...
  • Page 68 Chapter 7: Troubleshooting and Support Note: Do not interrupt this process until the BIOS flashing is complete. 9. The screen above indicates that the BIOS update process is complete. When you see the screen above, unplug the AC or DC power cable from the power supply, clear CMOS, and plug the AC or DC power cable in the power supply again to power on the system.
  • Page 69: Cmos Clear

    Chapter 7: Troubleshooting and Support 7.6 CMOS Clear JBT1 is used to clear CMOS, which will also clear any passwords. Instead of pins, this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS. To Clear CMOS 1.
  • Page 70: Where To Get Replacement Components

    7.8 Where to Get Replacement Components If you need replacement parts for your system, to ensure the highest level of professional service and technical support, purchase exclusively from our Supermicro Authorized Distributors/System Integrators/Resellers. A list can be found at: http://www.supermicro.com.
  • Page 71: Vendor Support Filing System

    For issues related to Red Hat Enterprise Linux, since it is a subscription based OS, contact your account representative. 7.10 Feedback Supermicro values your feedback as we strive to improve our customer experience in all facets of our business. Please email us at techwriterteam@supermicro.com to provide feedback on our manuals.
  • Page 72: Contacting Supermicro

    Chapter 7: Troubleshooting and Support 7.11 Contacting Supermicro Headquarters Address: Super Micro Computer, Inc. 980 Rock Ave. San Jose, CA 95131 U.S.A. Tel: +1 (408) 503-8000 Fax: +1 (408) 503-8008 Email: marketing@supermicro.com (General Information) support@supermicro.com (Technical Support) Website: www.supermicro.com Europe Address: Super Micro Computer B.V.
  • Page 73: Appendix A Standardized Warning Statements For Ac Systems

    Should you have questions or experience difficulty, contact Supermicro's Technical Support department for assistance. Only certified technicians should attempt to install or configure components. Read this appendix in its entirety before installing or configuring components in the Supermicro chassis. T h e s e...
  • Page 74 Appendix A: Warning Statements Warnung WICHTIGE SICHERHEITSHINWEISE Dieses Warnsymbol bedeutet Gefahr. Sie befinden sich in einer Situation, die zu Verletzungen führen kann. Machen Sie sich vor der Arbeit mit Geräten mit den Gefahren elektrischer Schaltungen und den üblichen Verfahren zur Vorbeugung vor Unfällen vertraut. Suchen Sie mit der am Ende jeder Warnung angegebenen Anweisungsnummer nach der jeweiligen Übersetzung in den übersetzten Sicherheitshinweisen, die zusammen mit diesem Gerät ausgeliefert wurden.
  • Page 75 Appendix A: Warning Statements . ٌ ‫ا ك ً ف حالة و ٌ يك أى تتسبب ف اصابة جسذ ة ٌ هذا الزهز ع ٌ خطز !تحذ ز‬ ‫قبل أى تعول عىل أي هعذات،يك عىل علن بالوخاطز ال ا ٌجوة عي الذوائز‬ ٍ...
  • Page 76 Appendix A: Warning Statements Warnung Vor dem Anschließen des Systems an die Stromquelle die Installationsanweisungen lesen. ¡Advertencia! Lea las instrucciones de instalación antes de conectar el sistema a la red de alimentación. Attention Avant de brancher le système sur la source d'alimentation, consulter les directives d'installation. .‫יש...
  • Page 77 Appendix A: Warning Statements Warnung Dieses Produkt ist darauf angewiesen, dass im Gebäude ein Kurzschluss- bzw. Überstromschutz installiert ist. Stellen Sie sicher, dass der Nennwert der Schutzvorrichtung nicht mehr als: 250 V, 20 A beträgt. ¡Advertencia! Este equipo utiliza el sistema de protección contra cortocircuitos (o sobrecorrientes) del edificio.
  • Page 78 Appendix A: Warning Statements Power Disconnection Warning Warning! The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. 電源切断の警告 システムコンポーネントの取り付けまたは取り外しのために、...
  • Page 79 Appendix A: Warning Statements ‫אזהרה מפני ניתוק חשמלי‬ ‫!אזהרה‬ ‫יש לנתק את המערכת מכל מקורות החשמל ויש להסיר את כבל החשמלי מהספק‬ ‫.לפני גישה לחלק הפנימי של המארז לצורך התקנת או הסרת רכיבים‬ ‫يجب فصم اننظاو من جميع مصادر انطاقت وإ ز انت سهك انكهرباء من وحدة امداد‬ ‫انطاقت...
  • Page 80 Appendix A: Warning Statements Attention Il est vivement recommandé de confier l'installation, le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés. !‫אזהרה‬ .‫צוות מוסמך בלבד רשאי להתקין, להחליף את הציוד או לתת שירות עבור הציוד‬ ‫واملدربيه...
  • Page 81 Appendix A: Warning Statements Warnung Diese Einheit ist zur Installation in Bereichen mit beschränktem Zutritt vorgesehen. Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug, Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich. ¡Advertencia! Esta unidad ha sido diseñada para instalación en áreas de acceso restringido. Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial, cerradura con llave u otro medio de seguridad.
  • Page 82 Appendix A: Warning Statements Battery Handling Warning! There is the danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions 電池の取り扱い...
  • Page 83 Appendix A: Warning Statements ‫هناك خطر من انفجار يف حالة اسحبذال البطارية بطريقة غري صحيحة فعليل‬ ‫اسحبذال البطارية‬ ‫فقط بنفس النىع أو ما يعادلها مام أوصث به الرشمة املصنعة‬ ‫جخلص من البطاريات املسحعملة وفقا لحعليامت الرشمة الصانعة‬ 경고! 배터리가 올바르게 교체되지 않으면 폭발의 위험이 있습니다. 기존 배터리와 동일하거나 제 조사에서...
  • Page 84 Appendix A: Warning Statements ¡Advertencia! Puede que esta unidad tenga más de una conexión para fuentes de alimentación. Para cortar por completo el suministro de energía, deben desconectarse todas las conexiones. Attention Cette unité peut avoir plus d'une connexion d'alimentation. Pour supprimer toute tension et tout courant électrique de l'unité, toutes les connexions d'alimentation doivent être débranchées.
  • Page 85 Appendix A: Warning Statements Backplane Voltage Warning! Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. バックプレーンの電圧 システムの稼働中は危険な電圧または電力が、 バックプレーン上にかかっています。 修理する際には注意く ださい。 警告 当系统正在进行时,背板上有很危险的电压或能量,进行维修时务必小心。 警告 當系統正在進行時,背板上有危險的電壓或能量,進行維修時務必小心。 Warnung Wenn das System in Betrieb ist, treten auf der Rückwandplatine gefährliche Spannungen oder Energien auf.
  • Page 86 Appendix A: Warning Statements ‫هناك خطز مه التيار الكهزبايئ أوالطاقة املىجىدة عىل اللىحة‬ ‫عندما يكىن النظام يعمل كه حذ ر ا عند خدمة هذا الجهاس‬ 경고! 시스템이 동작 중일 때 후면판 (Backplane)에는 위험한 전압이나 에너지가 발생 합니다. 서비스 작업 시 주의하십시오. Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is.
  • Page 87 Appendix A: Warning Statements ‫תיאום חוקי החשמל הארצי‬ !‫אזהרה‬ .‫התקנת הציוד חייבת להיות תואמת לחוקי החשמל המקומיים והארציים‬ ‫تركيب املعدات الكهربائية يجب أن ميتثل للقىاويه املحلية والىطىية املتعلقة‬ ‫بالكهرباء‬ 경고! 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다. Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften.
  • Page 88 Appendix A: Warning Statements Attention La mise au rebut ou le recyclage de ce produit sont généralement soumis à des lois et/ou directives de respect de l'environnement. Renseignez-vous auprès de l'organisme compétent. ‫סילוק המוצר‬ !‫אזהרה‬ .‫סילוק סופי של מוצר זה חייב להיות בהתאם להנחיות וחוקי המדינה‬ ‫التخلص...
  • Page 89 Appendix A: Warning Statements Warnung Gefährlich Bewegende Teile. Von den bewegenden Lüfterblätter fern halten. Die Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halten Sie Finger, Schraubendreher und andere Gegenstände von den Öffnungen des Lüftergehäuses entfernt.
  • Page 90 Verbindungskabeln, Stromkabeln und/oder Adapater, die Ihre örtlichen Sicherheitsstandards einhalten. Der Gebrauch von anderen Kabeln und Adapter können Fehlfunktionen oder Feuer verursachen. Die Richtlinien untersagen das Nutzen von UL oder CAS zertifizierten Kabeln (mit UL/CSA gekennzeichnet), an Geräten oder Produkten die nicht mit Supermicro gekennzeichnet sind.
  • Page 91 ‫.قيرح وأ لطع يف ببستي دق ىرخأ تالوحمو تالباك يأ مادختسا .ميلسلا سباقلاو لصوملا مجح‬ ‫ لبق نم ةدمتعملا تالباكلا مادختسا تادعملاو ةيئابرهكلا ةزهجألل ةمالسلا نوناق رظحي‬UL ‫ وأ‬CSA ‫( ةمالع لمحت يتلاو‬UL/CSA) ‫ لبق نم ةددحملاو ةينعملا تاجتنملا ريغ ىرخأ تادعم يأ عم‬Supermicro.
  • Page 92 사항을 준수하여 제공되거나 지정된 연결 혹은 구매 케이블, 전원 케이블 및 AC 어댑터를 사용하십시오. 다른 케이블이나 어댑터를 사용하면 오작동이나 화재가 발생할 수 있습니다. 전기 용품 안전법은 UL 또는 CSA 인증 케이블 (코드에 UL / CSA가 표시된 케이블)을 Supermicro 가 지정한 제품 이외의 전기 장치에 사용하는 것을 금지합니다. Stroomkabel en AC-Adapter...
  • Page 93: Appendix B System Specifications

    Appendix B: System Specifications Appendix B System Specifications Processor Support Single Intel® Xeon® processor E-2300 series and 10th Generation Pentium ® processors in an LGA1200 socket H5; Supports CPU TDP up to 95W. Note: Refer to the motherboard specifications pages on our website for updates to supported processors. Chipset Intel®...
  • Page 94 Appendix B: System Specifications Operating Environment Operating Temperature: 10º to 35º C (50º to 95º F) Non-operating Temperature: -40º to 60º C (-40º to 140º F) Operating Relative Humidity: 8% to 90% (non-condensing) Non-operating Relative Humidity: 5% to 95% (non-condensing) Regulatory Compliance FCC, ICES, CE, UKCA, VCCI, RCM, CSA/ UL, CB Applied Directives, Standards...
  • Page 95: Bsmi/Rohs

    Appendix B: System Specifications BSMI/RoHS 限 限 用 用 物 物 質 質 含 含 有 有 情 情 況 況 標 標 示 示 聲 聲 明 明 書 書 Declaration of the Presence Condition of the Restricted Substances Marking 設備名稱: 伺服器...
  • Page 96 Appendix B: System Specifications 輸入額定: 100-240V ~, 60-50Hz, 5-2.5A *使用者不能任意拆除或替換內部配備 *報驗義務人之姓名或名稱:美超微電腦股份有限公司 *報驗義務人之地址:新北市中和區建一路 150 號 3 樓...

Table of Contents