Other items
•
IQ Field Wireable Connectors (Q-CONN-R-10M and Q-CONN-R-10F): optional male and female
connectors (optional)
•
Number 2 and 3 screwdrivers
•
Wire cutters, voltmeter
•
Torque wrench, sockets, and wrenches for mounting hardware
Enphase microinverter installation
Installing the Enphase IQ Series Microinverters involves several key steps. Each step listed here is detailed on
the following pages:
Step 1: Position the IQ Cable
Step 2: Position the junction box
Step 3: Mount the microinverters
Step 4: Create an installation map
Step 5: Manage the cabling
Step 6: Connect the microinverters
Step 7: Terminate the unused end of the cable
Step 8: Complete the installation of the junction box
Step 9: Connect the PV modules
Step 10: Energize the system
Step 11: Set up and activate monitoring
Step 1: Position the IQ Cable
A. Plan each cable segment to allow drop connectors on the IQ Cable to align with each PV module.
Allow extra length for slack, cable turns, and any obstructions.
15
IQ7+/IQ7X/IQ7A Microinverters Installation and Operation Manual
© 2023 Enphase Energy Inc. All rights reserved.
August 2023