Safety and advisory symbols........................6 IQ7 Series Microinverter safety instruction ....................6 The Enphase IQ System ........................... 10 How the Enphase IQ Series Microinverter work? ..................10 System monitoring ..............................11 Optimal reliability ..............................11 Ease of design ................................ 11 Planning for microinverter installation ......................
User documentation is updated frequently; Check the Enphase website (enphase.com/support) for the latest information. To ensure optimal reliability and to meet warranty requirements, the Enphase microinverter must be installed according to the instructions in this manual. For warranty text refer to enphase.com/warranty.
Double-insulated Safety and advisory symbols To reduce the risk of electric shock, and to ensure the safe installation and operation of the Enphase IQ System, the following safety symbols appear throughout this document to indicate dangerous conditions and important safety instructions.
Page 7
You must protect each microinverter AC branch circuit with a 20 A maximum breaker or fuse as appropriate. DANGER: Risk of Do not use Enphase equipment in a manner not specified by the manufacturer. electric shock. Doing so may cause death or injury to persons or damage to equipment.
Page 8
DANGER: Risk of Do not attempt to repair the Enphase microinverter; it contains no user- electric shock. Risk serviceable parts. If it fails, contact Enphase customer service to obtain a return of fire. merchandise authorization (RMA) number and start the replacement process.
If a site has other IQ Series (IQ6, IQ7) Microinverters or M Series/S Series Microinverters, a split system needs to be created with IQ8 Microinverters provisioned on an IQ Gateway and the other microinverters provisioned on a separate IQ Gateway (for IQ6, IQ7) or IQ Gateway Metered (for M Series/S Series)
PV module. System monitoring Once you install the Enphase IQ Gateway and provide an internet connection through a broadband router or modem, the Enphase IQ Microinverters automatically begin reporting to Enphase App. The Enphase App presents current and historical system performance trends and informs you of PV system status.
IQ7X-96-2-INT MC-4 locking type Pair only with 96-cell modules NOTE: Some Enphase microinverters will not begin exporting power until the IQ is installed Gateway and has detected all the microinverters at the site. In addition, the grid profile may need to be configured and the IQ must have propagated these settings to the microinverters.
Select the correct wire size based on the distance from the beginning of the microinverter AC branch circuit to the breaker in the load centre. Enphase recommends a voltage rise total of less than 2% for the sections from the microinverter AC branch circuit to the breaker in the load centre.
Enphase IQ Gateway Installation and Operations Manual. • Enphase Installer App. • Download the Enphase Installer App and open it to log in to your Enphase Account. With this mobile app, you can scan microinverter serial numbers and connect to the IQ to track system Gateway installation progress.
• Torque wrench, sockets, and wrenches for mounting hardware Enphase microinverter installation Installing the Enphase IQ Series Microinverters involves several key steps. Each step listed here is detailed on the following pages: Step 1: Position the IQ Cable Step 2: Position the junction box...
Step 3: Mount the microinverters A. If the Enphase DC bulkhead connectors are not already attached to the microinverters, attach them now. Make sure they are fully seated. B. Mount the microinverter bracket side up (as shown) and under the PV module, away from rain and sun.
A. Peel the removable serial number label from each microinverter and affix it to the respective location on the paper installation map. B. Peel the label from the IQ Gateway and any Enphase Battery, if installed, and affix it to the installation map.
Enphase App, during system registration, or through Enphase Installer App at any time. You must have an Enphase IQ Gateway to set or change the grid profile. For more information on setting or changing the grid profile, refer to the Enphase IQ Gateway Installation and Operation Manual at enphase.com/support.
Enphase for possible replacement. Method 1: Clear this error using Enphase App • Log in to Enphase Installer App and access the system. • Click the “Events” tab. The next screen shows a current “DC Resistance Low - Power Off” condition for the system.
WARNING: Risk of electric shock. Always de-energize the AC branch circuit before servicing. Never disconnect the DC connectors under load. WARNING: The Enphase microinverters are powered by DC power from the PV modules. Make sure you disconnect the DC connections and reconnect the DC power and then watch for the solid green about six seconds after connection to DC power.
L. Swap DC leads with a known good, adjacent PV module. If after checking Enphase Installer Portal periodically (this may take up to 30 minutes), the problem moves to the adjacent module, this indicates that the PV module isn’t functioning correctly. If it stays in place, the problem is with the original microinverter.
H. Energize the AC branch circuit breaker and verify the operation of the replacement microinverter by checking the Status LED on the connector side of the microinverter. Use the Enphase Installer App to delete the old microinverter serial number from the Enphase IQ database. In Enphase Installer App, once connected to the IQ...
The Microinverter Communications LED flashes green during the scan. K. Log in to Enphase App to use Enphase Installer App’s array builder to add the newly detected microinverter to the virtual array.
Group 1: Frequency Shift with continuous positive frequency PIQ capability curve If needed, Enphase IQ7 Series Microinverters have the capability to absorb or inject reactive power, provided that current and voltage ratings are not exceeded. The following figure shows the active power (P) capabilities curve relative to reactive power (Q) related to the power rating in the operating voltage range for Enphase IQ7 Series.
IQ7+/IQ7X/IQ7A Microinverters Installation and Operation Manual IQ7 Series PQ capability curve Specifications The following tables list specifications for the various IQ7 Series models and the IQ Cable. IQ7-60-2-INT Microinverter specifications Enphase IQ7-60-2-INT Microinverter parameters Topic Unit Typical DC parameters Commonly used module pairings 235−350+...