Specification
Voltage rating
Voltage withstand test (kV/1min)
Max DC conductor resistance
(20ºC) (Ω/km)
System temperature range
(ambient)
Cable temperature rating
Cable rating
Certification
Flame rating
Cable conductor insulator rating
Environmental protection rating
UV resistance
UV exposure rating
Compliance
Maximum loop size
38
IQ7+/IQ7X/IQ7A Microinverters Installation and Operation Manual
H07BQ-F Cable
(without "-A" designation)
450/750 V
(connector rating up to 250 V)
AC 3.0
5.433
-40°C to 65°C
90°C Dry/90°C Wet
H07BQ-F
EN 50525-2-21
IEC 60332-1-2
H07BQ-F
IEC 60529 IP67
1008 Hr
IEC60068-2-5
RoHS, OIL RES I, CE, UV
Resistant
12 cm
© 2023 Enphase Energy Inc. All rights reserved.
IEC60227 Cable
(with "-A" designation)
300/500 V
AC 2.0
7.98
-40°C to 65°C
90°C Dry/90°C Wet
IEC57
IEC 60227
IEC 60332-1-2
IEC60227, IEC57 RVV-90
IEC 60529 IP67
1008 Hr
IEC60068-2-5
RoHS, WEEE, CE
8 cm