Parts And Tools Required; Enphase Equipment; Other Items; Lightning And Surge Suppression - enphase M215-60-2LL-S25-IG Manual

Microinverter
Table of Contents

Advertisement

Parts and Tools Required

In addition to the microinverters, PV modules, and racking, you will need the following.

Enphase Equipment

Enphase Envoy Communications Gateway (optional, but recommended)
BEST PRACTICE: Connect the Envoy before the solar installation is complete.
When powered up and connected for the first time, the Envoy may retrieve an automatic
upgrade from Enphase. Because this upgrade may take up to 20 minutes, connect the
Envoy first (connect to both AC power and to the broadband router) so that it performs
the upgrade well before the solar module installation is complete. For more information,
see the Envoy Communications Gateway Installation and Operation Manual.
Engage Cable, as needed. (See "Engage Cable Planning and Ordering Information" on page 26.)
NOTE: Order the correct Engage Cable type. Installers must order Engage Cable for
either 240 VAC single phase, typical for residential applications, or 208 VAC three phase,
typical for commercial installations. All drop connectors on the Engage Cable bear labels
indicating the cable voltage designation.
Cable clips
Sealing caps, as needed (for any unused drops on the Engage Cable)
Terminators, as needed (one needed at the end of each AC branch circuit)
Enphase disconnect tool (number 2 and 3 Phillips screwdrivers can be substituted)

Other Items

Outdoor-rated, weather-proof AC junction box(es)
Gland or strain relief fitting (one per AC junction box)
Number 2 and 3 Phillips screwdrivers
Torque wrench, sockets, wrenches for mounting hardware
Adjustable wrench or open-ended wrench (for terminators)
Handheld mirror (to view LEDs on the undersides of the microinverters)

Lightning and Surge Suppression

Enphase Microinverters have integral surge protection, greater than most traditional inverters. However, if
the surge has sufficient energy, the protection built into the microinverter can be exceeded, and the
equipment can be damaged. For this reason, Enphase recommends that you protect your system with
lightning and/or surge suppression devices. In addition to having some level of surge suppression, it is
also important to have insurance that protects against lightning and electrical surges.
Install these devices per vendor instructions.
Residential
 Citel DS72-RS-120 surge protector;
 Delta LA-302 lightning arrestor;
 Leviton 51110 or 51110-001; whole house surge
protection panel;
website
 Midnight solar surge protection device MNSPD-300 or
MNSPD-300FM (with flush mount box);
8
data sheet
website
website
 2013 Enphase Energy Inc.
M250 Installation and Operation
Commercial
 Citel DS73-RS-G surge protector;
 Delta LA-303 lightning arrestor;
data sheet
website
141-00022 Rev 01

Advertisement

Table of Contents
loading

Table of Contents