Summary of Contents for Regency Fireplace Products CF780
Page 1
Owners & CF780 Wood Fireplace Installation Manual If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Please read the entire manual before you install and use your appliance. Follow the instructions in the installation manual for proper use.
Page 2
REGENCY DEALER in your area. Keep those REGENCY FIRES burning. The Regency CF780 wood fireplace ia a decorative appliance that provides aesthetic enjoyment with over 700 square inches of fire viewing area. This fireplace is defined as a fireplace (primarily for aesthetics) under the 2015 regulations.
Installing The Cement Board Panels ......24 Vermiculite smoke chamber panels ......45 Spark Guard ..............25 Brick Liners ..............45 CF780 Brick Installation ..........26 CF780 Andirons/ Fire dog Installation ......26 Warranty ..............48 Gas Log Installation .............27 Side shield installation ..........28 CF780 Wood Fireplace |...
Page 4
CF780 is tested and certified to ULC S610-M87 (R2018) and UL 127-2011 (R2015). Install and use only in accordance with the manufacturer's installation and operating instructions. Le modèle CF780 est testé et homologué selon les normes ULC S610-M87 (R2018) et UL 127-2011 (R2015). À installer et à utiliser uniquement en suivant les consignes d'installation et d'utilisation du fabricant.
PROBLEMS. 4. DO NOT use the fireplace with the door closed if the glass is THE CF780 IS CAPABLE OF BURNING CLEANLY PRIMARILY BECAUSE cracked or broken. Replace the glass before using the glass door IT HAS BEEN ENGINEERED TO QUICKLY BURN VERY HOT. THIS again.
4. Remove the floor standoff that is secured with 4 x 5/16" hex head screws of the unit. NOTE - replace 2 x 1\4" screws when bracket is removed. From to the back of appliance. the interior remove 2 x 5/16" screws to completely remove bracket. | CF780 Wood Fireplace...
The anchor plate height will vary depending on the specific chimney manufacturer. See specific chimney manufactured product catalogue for complete details. ALL PICTURES / DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY. ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS. CF780 Wood Fireplace |...
Refer to L on Table 1 (next page) Refer to N on Table 1 (next page) Refer to C on Table 1 (next page) Refer to I on Table 1 (next page) Refer to H on Table 1 (next page) | CF780 Wood Fireplace...
Page 9
Minimum distance between each combustible mantel leg and the fireplace open- ing (refer to the “INSTALLATION: Mantel” section for details) See Table 3 Note: For 45°corner installs: 3" clearance is required from back corners of unit. " " CF780 Wood Fireplace |...
The only combustible material accepted on the facing of the fireplace is for a mantel (shelf and posts). If you need to attach the mantel to the front of the fireplace refer to page 23 to see where screws are permitted on the front of the fireplace facing. | CF780 Wood Fireplace...
Steel Studs Wood Stud Location The CF780 must be installed within the vapor barrier of the home. It cannot be installed outside, or on a three season porch. Your CF780 fireplace may be installed in different ways (see Diagram of framing examples).
Note: The ventilation grills must be located within the confines of the framed chase. *See location note *See location note *Must be located between 3"-12" of chase enclosure *See location note *See location note Must be located between 3"-12" of chase enclosure CF780 Wood Fireplace |...
Combustible Floor: Bottom standoff If the CF780 is installed on any type of combustible floor surface or structure, you MUST install the fireplace onto the fireplace bottom standoff provided with tooltip the fireplace.
Duct Tape Outside Air Inlet: either above or below the level of the fireplace Outside Air Connection and Installation Example CAUTION: WHEN RUNNING THE DUCT AROUND CORNERS, AVOID CRUSHING THE DUCT WHICH CAN RESTRICT THE COMBUSTION AIRFLOW. CF780 Wood Fireplace |...
Chimney System Considerations Regency’s CF780 Fireplace is to be installed with one of the following Chimney Systems only. Chimney systems only 8" (203mm) diameter are to be used that comply to ULCS 629 for CDN and UL103HT for USA.
1'. For example, if you are living 6000' above sea level, your chimney should terminate at least 15’ from the top of the fireplace (12’ + 3’ for the 6000’). See Table 4 for more precise recommended flue heights. ** 45 degree elbows are not permitted for use in the U.S.A. CF780 Wood Fireplace |...
If the chimney is higher than 5’ above the roof, it must be secured using a roof brace. For manufactured homes the roof thimble assembly shall extend com- pletely through the ceiling/roof cavity of the manufactured home to the outer most plane of the roof. | CF780 Wood Fireplace...
Page 19
The smaller end goes towards the floor while the larger end goes towards the ceiling. Make sure to CF780 Wood Fireplace | insert the flexible radiation shield tube in the appropriate orientation around...
9 ' 9¼ " 8' 9 " Height of the 9 ' 4 " | CF780 Wood Fireplace center of the hole if not using the 8' 3½" if not using the in the wallA bottom standoff...
The enclosure walls can be framed with any suitable materials (2"x4" or 2"x6" studs, plywood, gypsum board, etc.). Because of the high heat output potential of the RUMFORD 1500, combustible materials must NOT go closer to the fireplace than the top, CF780 Wood Fireplace | back and sides' standoffs, refer to Figure 3.
The Gravity Air Feed Kit is designed to extend the heat output vent above the CF780 to the front or the side. The flex vent is connected to the vent holes in the top of the unit and run to discharge vent grilles. Both 8" (203mm) diameter 6"...
The enclosure walls can be framed with any suitable materials (2"x 4"or 2" x 6" studs, plywood, gypsum board, etc.). Because of the high heat output potential of the CF780, combustible materials must NOT be used on the entire front of the unit. Use only steel studs, non-combustible board,and non-combustible materials.
* This allows for 1-1/2" (38 mm) of facing material to be added to the perimeter of the lintel. If using thinner material furring strips can be added to reduce the depth of lintel. *1-1/2" Lintel " " " 8 " Side View | CF780 Wood Fireplace...
4. Remove smoke deflector and support (2 pieces) by to present. lifting up and out. The CF780 has 2 options for the bricks that line the interior 5. Install lower center brick (1) and hold in place. of the firebox. One of the two options MUST be installed.
1. Slide the fire dogs through the andiron pushing them to the back wall of the unit until they reach the back brick as shown in Diagram 5 below. Firedogs Andiron installed Diagram 5 - Andirons Page 1 of 1 096-500.SLDASM 12/20/2019 920-208 12.23.19 CF780 Wood Fireplace |...
3. Drill through the brick panel on the side chosen to bring in the gas line using a masonry bit. Drill carefully as brick panels are prone to cracking. tooltip Gas line opening in unit Drill through panel (either side) for gas line | CF780 Wood Fireplace...
2. Install the “Finish Side Shield” (smaller of the 2 finished pieces) into the locked slots located on the bottom and side, directly in- between the firescreen and glass door. 3. The “Front Finish Side Shield” is placed into similar slots located in front of the firescreen door. Finish Side Shield Front Finish Side Shield CF780 Wood Fireplace |...
For a warmer fire, load 3 to 4 medium logs (5” diameter) or 2 to 3 large logs To light a fire in your CF780, place a few pieces of bunched up paper under (6” diameter) either lying down on the andirons or standing up in a teepee- and between the andirons.
Outside Air Control The CF780 is designed to have optional outside air. The control for the outside air is located on the left side beyond the door rail (see Diagram). This control closes the damper when not in use.
Use operating tool to lift screen Note: Fire screen must be fully closed during operation. Ensure you have established a hot fire before using the fire screen. Only use fire screen door frame (Part #096-513) provided with appliance. | CF780 Wood Fireplace...
3. Pull latch up to release door. 4. Swing door open–clean glass as per glass cleaning instructions in this manual. 5. Reverse steps to close door. tooltip Door tool in door latch Swing door to the left to open CF780 Wood Fireplace |...
General Cleaning Chimney Cleaning A fireplace as clean burning as the CF780 does not produce a lot of creosote Any black painted portion of the fireplace can be cleaned with a soft damp cloth. but the chimney should still be inspected for creosote buildup after a couple Use a mild detergent and water.
2. Remove the smoke deflector (as shown in the image below) by lifting it up and over the flange it is sitting on. 5. Ensure the weight is facing you when attaching the new damper. CF780 Wood Fireplace |...
2. Slide the screen door up and out of the way. 3. Using an Allen key–remove 2 screws on each side (located behind the door tracks) in locations shown below. tooltip Tilt bottom of screen out to remove Remove 4 screws | CF780 Wood Fireplace...
9. Remove 2—3/8"bolts (shown in Note: Once the glass is removed, the door frame will move upwards due to diagram) to remove and replace the counterweights. tooltip latch assembly. CF780 Wood Fireplace |...
Once the cable is around the pulley, pull the cable down and hook it on the side. Cable Weight 3. Repeat previous step (2) with the back cables. | CF780 Wood Fireplace...
This appliance does have an internal damper inside of the 8" flue. Be careful not to damage this when cleaning the chimney. The damper will be located inside of the 8 inch flue approximately 3 feet up from inside of the fireplace ceiling. CF780 Wood Fireplace |...
Door Assembly 096-548 Door Frame Assembly 948-504 Stainless steel slider (set of 2) 096-059 Slide mounting bracket 096-108/F Air deflector 940-505/P Ceramic door glass 096-009 Door latch See next page Door frame - Assembly - No Glass | CF780 Wood Fireplace...
Page 45
Door Assembly - No Glass 096-547 Door Frame Assembly 936-243 Tape 7/8 Window Adhesive (sold per ft./12 ft required) 096-006 Glass Bracket 096-007 Glass Bracket Right Side 096-008 Glass Bracket Left Side CF780 Wood Fireplace |...
Brick Liners (contemporary) 096-077/P Top Middle 096-076/P Top Left 096-078/P Top Right 096-079/P Left Floor 096-080/P Right Floor 096-073/P Bottom Left 096-074/P Bottom Middle 096-075/P Bottom Right 096-901 Complete Set ITEM NO. PART NUMBER 096-077 | CF780 Wood Fireplace 096-076 096-078...
Page 47
096-176/P Top Left 096-178/P Top Right 096-079/P Left Floor 096-080/P Right Floor 096-173/P Bottom Left 096-174/P Bottom Middle 096-175/P Bottom Right 096-902 Complete Set ITEM NO. PART NUMBER 096-077 096-076 096-078 096-079 096-080 096-073 096-074 096-075 CF780 Wood Fireplace |...
Incomplete claims may be rejected. Replacement units are limited to one per warranty term. Unit must be installed according to all manufacturers’ instructions as per the manual. CF780 Wood Fireplace | Revision Date: June 2019 Regency Wood Products Warranty...
Page 50
Freight damages for products or parts are not covered under the terms of the warranty. Products made or provided by other manufacturers and used in conjunction with the FPI appliance without prior authorization from FPI may void this warranty. Revision Date: June 2019 Regency Wood Products Warranty | CF780 Wood Fireplace...
Page 51
To provide the best support for your product, we request that you complete a product registration form at http://www.regency-fire.com/Customer-Care/Warranty-Registration.aspx within ninety (90) days of purchase. Revision Date: June 2019 Regency Wood Products Warranty CF780 Wood Fireplace |...
Page 52
For fireplace care and tips and answers to most common questions please visit our Customer Care section on our Web Site. Please feel free to contact your selling dealer if you have any questions about your Regency product. | CF780 Wood Fireplace...
Need help?
Do you have a question about the CF780 and is the answer not in the manual?
Questions and answers