Venting Introduction (Non Power Vent)

The CP60E uses the "balanced flue" technology coaxial system. The inner liner vents products of combustion to the outside while the outer liner draws outside
combustion air into the combustion chamber, thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.
The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel
or gas burning appliance. Each direct vent gas appliance must use its own separate vent system. Common vent systems are prohibited.
• These flue pipes must not be connected to any other appliance.

Venting Arrangement for Horizontal Terminations (Rigid and Flex)

The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90
• Must use optional rigid pipe adapter (part# 770-994) when using rigid pipe venting systems.
• For horizontal terminations, the Regency direct vent flex system may be used for installations with a maximum continuous vent length of up to 10
feet. If longer runs are required, rigid pipe must be used.
VENT RESTRICTOR SETTING:
Vent restrictor factory set at Set 0.
Refer to the "Vent Restrictor Position" section for details on how to change the vent restrictor from the factory setting of Set 0 to Set 2 if required.
Maintain clearances to combustibles as listed in "Clearances" section
Horizontal vent must be supported every 3 feet.
Firestops are required at each floor level and whenever passing through a wall.
A vent guard should be used whenever the termination is lower than the specified minimum or as per local codes.
54
| City Series CP60E
Vent Restrictor
Set 3: 2-3/8" Open
Vent Restrictor
Set 2: 3-1/8" Open
Set 0
Fully Open
Factory Set
46-1/4" (1175
mm)
Minimum Height
Requirement
3RD ANGLE
TOLERANCES UNLESS
PROJECTION
OTHERWISE STATED
DIMENSIONS
0.000 = 0.01 CRITICAL
0.000 = SPECIFIED TOLERANCE
DO NOT SCALE
0.000 = 0.031
DRAWING
0.000 REF = REFERENCE ONLY
UNITS IN INCHES
ANGULAR = 1
THIS DRAWING IS THE PROPERTY OF FPI LTD., IT MAY NOT BE COPIED IN WHOLE OR IN PART, OR DISCLOSED TO A THIRD PARTY WITHOUT OUR PRIOR WRITTEN CONSENT.
elbow (two 45
o
FIREPLACE PRODUCTS
-
MAT'L :
INTERNATIONAL
SHEAR/ PUNCH/ FORM
PROCESS :
1:24
CP60 MAIN ASSEMBLY
SCALE:
PART :
11/17/2021
MEDRALIN
PART NO:
DWN:
DATE:
457-500
E.C.N.:
SIGN:
DATE:
elbows equal one 90
elbow).
o
o
REV:
-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp60e-ngCp60e-lp

Table of Contents