Aeration Adjustment; Minimum Air Shutter Opening - Regency Fireplace Products City CP60E Series Owners & Installation Manual

Table of Contents

Advertisement

maintenance

Aeration Adjustment

The burner aeration is factory set, but may need adjusting due to the local
gas supply or altitude. Open the air shutter for a blue flame or close for a
more yellow flame.
• If the firebox glass, logs, inner panels, etc. are already installed, the
aeration can be adjusted from outside the firebox.
• Aeration will be located on side A of the appliance.
1. Remove the centre access panel on the outer trim. If finishing material is
already installed, remove the glass safety barrier and center outer panel.
See instructions in this manual.
2. Attach the handle to the aeration lever through the access opening. The
handle will slide into position on the lever.
Remove
3. Adjust aeration accordingly.
Pushing lever in opens the air shutter.
Pulling the lever outward closes the air shutter.
aeration
handle
• The aeration handle is located near the right side of the gas
valve access door, attached by a magnet.
100
| City Series CP60E

Minimum Air Shutter Opening

NG, NG with logs, NG with volcanic stones: 3/16" (5 mm)
LP, LP with logs, LP with volcanic stones:
4. Remove the handle by lifting up and out. Replace the access door and
tighten the two screws. Hang the handle back onto the magnet.
5. Reverse to Step 1.
• Any damage due to carboning resulting from improperly setting the
aeration controls is NOT covered under warranty.
3/8" (9-1/2 mm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cp60e-ngCp60e-lp

Table of Contents