Replacing The Lcm - Spectra Logic T-Series Spectra T50e Hardware Replacement Manual

Library control module replacement instructions
Hide thumbs Also See for T-Series Spectra T50e:
Table of Contents

Advertisement

Replacing the LCM

Removing the LCM
1. Power off the library—press and hold the front panel power button for one
second.The power-off sequence takes approximately two minutes while the library
allows applications to shut down gracefully.
Figure 2 LCM replace–power off the library.
2. Disconnect any cables connected to the LCM and remove any USB devices, if
present.
3. Loosen the finger screws securing the LCM to the chassis by hand or with a
#2 Phillips screwdriver (Figure 3).
Figure 3 Remove the screws securing the LCM to the chassis.
4. Grasp the thumb screws and pull the LCM directly toward you to slide it out of the
chassis.
5. Set the LCM aside for return to Spectra Logic.
Replacing the LCM
Power button
Thumb screws
(one each side)
13