Library control module replacement instructions
Hide thumbs Also See for T-Series Spectra T50e:
Table of Contents

Advertisement

Returning Components

Rebuild the configuration in this order:
1. Option keys
2. Encryption keys
3. Partitions
4. Networking
5. Email and SMTP information
6. Date and Time
7. Settings
8. AutoSupport Log profiles
9. Users and passwords

Restarting Backups

After you restore the library configuration and the library finishes rebooting, use your
backup software to restart any backup processes.
Storing Configuration Changes
Spectra Logic recommends that you always store a copy of the current library
configuration on a USB device. Any time you make a change to a partition parameter,
the library asks you to save the configuration change to a USB device; Spectra Logic
recommends taking advantage of this feature.
Returning Components
After you complete the replacement procedure, return the malfunctioning component
to Spectra Logic.

Packaging a Component for Shipment

Note:
Use the packaging from the replacement component to pack the
component you are returning. The packaging may look somewhat
different from that shown in this section.
1. Place the component inside the anti-static bag.
18