Handpiece Vacuum/Pressure - Pace ST 85 Operation & Maintenance Manual

Table of Contents

Advertisement

1. Attach a length of Small, Flexible Air Hose (not supplied) to the Air Hose Fitting on
the rear of the PACE power source using the following procedure.
PACE does not recommend the attachment of quick connect air hose
fittings to the power source. The weight of the standard large air hose
lines will affect the stability of the system and would require a larger
bench space.
a) 230 VAC Systems only: A metric adapter fitting (PACE part number
1259-0081) is included for use with 230 VAC systems.
DO NOT overtighten connections. Damage to
the system could occur if excessive torque is
applied to the Air Hose Fitting, metric adapter
or Connector.
b) Install the Connector (with Small,
Flexible Air Hose) onto the Air
Hose Fitting (or metric adapter)
finger tight. Using an appropriate
wrench, tighten the Connector an
additional 1/4 turn. DO NOT
overtighten.
2. Connect the free end of the small,
flexible air line to your air supply
using the appropriate fittings.

Handpiece Vacuum/Pressure

To set up your Sodr-X-Tractor air hose connection, perform the following steps:
1.Air Hose To Handpiece Connection
a) Attach one end of a 137cm (54 inch) length of air hose to the metal tube in the
back of the handpiece.
b) If you have a PACE system incorporating only one handpiece, attach the air
hose to the power cable using the supplied Hose Clamps. Space them evenly
along the length of the power cable starting at a point 6 inches from the ends
of the handpiece.
c) If you have a PACE system incorporating 2 or more air handpieces, you may
wish to leave the air hose assembly unattached to allow a quick change to
any air handpiece being used.
NOTE
Set-Up
15