PACE factory specifications) or the temperature setting normally used by the operator. If
the temperature displayed on temperature meter is within ±15°C (27°F), perform steps 4
thru 6 to obtain a precise reading. If the temperature is off by more than ±15°C, the
handpiece may require maintenance.
second handpiece.
4. Carefully lock the Variable Temperature Control in position by tightening the
inner set screw (closest to front panel).
5. Loosen the outer set screw on the Variable Temperature Control knob (furthest
from front panel) using the Temp. Locking Key (hex key) supplied with the
system. Position the knob with the pointer aligned to match the temperature
indicated on the temperature meter. Secure the knob in position by tightening
the outer set screw.
Temperature control if adjustment of operating tip temperature is desired.

Vacuum Pump Operation

The PACE ST 125 contains two different vacuum pumps.
1. HiFlo Pump
a) To activate, depress the handpiece activation button.
b) Optional Foot Pedal can be used to actuate the HiFlo pump via the rear TEKLINK
socket.
2. LoFlo Pump
a) This pump is activated by the front Illuminated LoFlo Pump Switch.
b) Used for the TJ-70/80 and PV-65 Pik Vac Wand.
CAUTION: Ensure that only one air hose is connected to the VACUUM or controllable PRESSURE
port at one time. Attachment to both ports simultaneously will cause deterioration in
performance.
Handpiece Vacuum/Pressure
To set up your Sodr-X-Tractor air hose connection, perform the following steps:
1. Air Hose To Handpiece Connection:
a) Attach one end of a 137cm (54 inch) length of air hose to the metal
tube in the back of the handpiece.
b) If you have a PACE system incorporating only one handpiece, attach
the air hose to the power cable using the supplied Hose Clamps.
Space them evenly along the length of the power cable starting at a
point 6 inches from the ends of the handpiece.
c) If you have a PACE system incorporating 2 or more air handpieces,
you may wish to leave the air hose assembly unattached to allow a quick change to any
air handpiece being used.
2. Prepare a VisiFilter in the following manner: