Before installation and commissioning

Safety

Danger from incorrect operation and work that is not carried out properly.
This can result in serious personal injury and damage to property.

Proper use

The power source may only be used for MIG/MAG, MMA and TIG welding. Any
use above and beyond this purpose is deemed improper. The manufacturer shall
not be held liable for any damage arising from such usage.
Proper use also includes:
-
-
Setup regula-
The device has been tested according to degree of protection IP23. This means:
tions
-
-
The device can be set up and operated outdoors in accordance with protection
class IP23. Direct moisture (e.g., from rain) must be avoided.
Danger from machines toppling over or falling.
This can result in serious personal injury and damage to property.
The ventilation channel is a very important safety device. When selecting the
setup location, ensure that the cooling air can enter or exit unhindered through
the vents on the front and back. Any electrically conductive dust (e.g., from
grinding work) must not be allowed to be sucked directly into the system.
Mains connec-
-
tion
-
-
-
60
WARNING!
All the work and functions described in this document must only be carried
out by technically trained and qualified personnel.
Read and understand this document in full.
Read and understand all safety rules and user documentation for this device
and all system components.
following all the information in the operating instructions
carrying out all the specified inspection and servicing work
Protection against solid foreign bodies larger than Ø 12.5 mm (0.49 in.)
Protection against spraywater at any angle up to 60° from the vertical
WARNING!
Set up the device securely on an even, solid surface.
Check all screw connections are tightly fastened after installation.
The devices are designed for the mains voltage specified on the rating plate.
Devices with a nominal voltage of 3 x 575 V must be operated on three-phase
systems with earthed star point.
If your version of the appliance does not come with mains cables and mains
plugs ready-fitted, these must be fitted by a qualified person in accordance
with national standards.
The fuse protection for the mains lead is indicated in the technical data.