Step 2
Select a channel and AI type.
Step 3
Click
to enable the function.
Step 4
Configure the sensitivity.
The higher the value, the easier it is to trigger an alarm. But meanwhile, the false alarm
might occur. The default value is recommended.
Step 5
Select effective target from Human and Motor Vehicle.
Click Setting next to schedule to configure the alarm period.
Step 6
Step 7
Configure alarm linkage.
Parameter
Description
The system records only one motion detection event within the defined
Anti-Dither
period.
Alarm-out Port
When an alarm occurs, the NVR links the alarm output device to generate
an alarm. The alarm lasts a period of time depending on the defined value
for Post-Alarm.
Post-Alarm
●
●
Show Message
Enable on-screen prompt when an alarm occurs.
Figure 5-175 SMD
Table 5-47 Alarm linkage parameters
Make sure that the alarm devices are connected to the alarm output
port of NVR.
In Main Menu > ALARM > Alarm-out Port, set the mode to Auto so
that the system can link the alarm output device to generate an alarm.
289
User's Manual