4. Click Apply.
Click Apply.
Step 6
5.9.7.2.5 People Stay Detection
When the target stays in the detection area longer than the defined duration, an alarm will be
triggered.
Procedure
Select Main Menu > AI > Parameters > Stereo Analysis.
Step 1
Select a channel and then click Add.
Step 2
Select Enable and then set Type to People Stay Detection.
Step 3
Step 4
Draw detection rule.
1. Click
stop drawing.
2. Configure parameters.
Parameter
Name
Sensitivity
Duration
Repeat Alarm Time
3. Click OK.
Step 5
Configure alarm schedule and linkage.
1. Click
2. Click Setting next to Schedule to configure the alarm period.
The system performs linkage actions only for alarms during the arming period.
, and then draw a detection area on the video image. Right-click the image to
Table 5-44 Parameters of people stay detection
Description
Customize the rule name.
Set alarm sensitivity.
Set low long people stay in the detection area until an alarm is
triggered.
Set repeat alarm time. If the alarm-triggering event continues, an alarm
will be triggered again when repeat alarm time passed.
Figure 5-153 Schedule and alarm linkage
.
On the time line, drag to set the period.
You can also click
to set the period.
266