Manual
00809-0500-4881
1.3
Specifications
Note
All static performance characteristics are with operating variables constant. Specifications
subject to change without notice.
1.3.1
Net O
0-1 percent to 0-40 percent O
1.3.2
Combustibles
0-1000 ppm to 0-5 percent, fully field selectable
1.3.3
Accuracy
Oxygen
±0.75 percent of reading or 0.5 percent O
Combustibles
±50 ppm
1.3.4
System response to test gas
Oxygen
10 seconds T90
Combustibles
25 seconds T90
1.3.5
Temperature limits
Process
32 to 2600 °F (0 to 1427 °C)
Sensors housing
-40 to 212 °F (-40 to 100 °C) ambient
Electronics housing
-40 to 149 °F (-40 to 65 °C), ambient
-40 to 185 °F (-40 to 85 °C), internal operating temperature of electronics inside housing, as
read by HART
Rosemount OCX8800C
range
2
, fully field selectable
2
, F
Fieldbus, or AMS software.
®
™
OUNDATION
Description and specifications
(whichever is greater)
2
April 2023