PR150 BC Ice Drink Dispenser Operator's Manual

INSTALLATION INSTRUCTIONS

Counter Height (inches)
30
31
32
33
34
34-1/2
35
36
C
I
OUNTERTOP
NSTALLATION
!
WARNING:
It is the responsibility of the installer to ensure that the water supply to the dispensing equipment is provided with
protection against backflow by an air gap as defined in ANSI/ASME A112. 1.2-1976; or an approved vacuum breaker
or other such method as proved effective by test and must comply with all federal, state and local codes.
Failure to comply could result in serious injury, death or damage to the equipment.
IMPORTANT: Water pipe connections and fixtures directly connected to a potable water supply must be sized,
installed, and maintained according to federal, state and local laws.
1.
Locate the dispenser indoors on a level countertop.
must
The dispenser
must
opening that
outline dimension on the countertop using the dimensions given or use the full size template enclosed.
Apply a continuous bead of NSF International (NSF) listed silastic sealant (Dow 732 or equivalent) approximately
1/4 inch inside the dispenser outline dimensions and around all openings. Position the dispenser on the countertop
within the outline dimensions. All excess sealant
2.
The drain tube is routed through the large opening in the bottom of the dispenser. See the MOUNTING
TEMPLATE (see Figure 1) for locating the required clearance hole in the countertop for these utility lines.
The power cord is routed through hole in the side of the dispenser electrical control box.
3.
SINK DRAIN ASSEMBLY: Connect the drain tube to an open drain. Additional drain tubing is provided
with the Dispenser. The drain tube
drainage will result.
A.
Use 3/4-inch nominal plastic pipe.
B.
To assure proper drainage,
dispenser.
4. Clean the hopper interior (See CLEANING INSTRUCTIONS).
5. Connect dispenser power cord to 120 VAC 60 HZ 15-Amp 3-wire grounded receptacle.
Publication Number: 620918702
Dispenser Depth (inches
29
29
29
29
29
29
29
29
be sealed to the countertop. The MOUNTING TEMPLATE (see Figure 1) indicates the
be cut in the countertop. Locate the desired position for the dispenser, then mark the
must
must
continuously pitch downward and contain no "traps" or improper
do not
allow a "trap" to form in the drain line.
Available Space Below
Dispenser (inches)
1
2
3
4
5
5-1/2
6
7
be wiped away immediately.
Be sure
- 4 -
Use Kit No.
Consult Factory
Consult factory
620517502
and
629087406
629087406
629087406
629087412
and
620517502
629087412
629087412
drain line runs flat with bottom of the